Kiturami gas heating boilers are the art of heating from South Korea. Overview of Kiturami boilers What is the peculiarity of heating equipment from Kiturami

Despite the development of alternative energy, humanity is still actively using the usual sources of energy, in particular, gas. The South Korean manufacturer has been producing heating boilers for more than a decade and is rightfully one of the world leaders in this field. It makes sense to dwell on the products of this manufacturer.

About Kiturami products

The company was founded in 1962 and has been honing its craftsmanship in the production of heating boilers over the years. During this time, the company's products have gained confidence in the markets of Russia, Japan, Europe and the rest of the world.

The main activity of the manufacturer is the production of heating boilers, chimneys and other elements necessary for the installation of the heating system.

You can select such types of products as:

  • boilers, and models are available that run on both gas and liquid or solid fuels. Solid fuel boilers Kiturami can work either on ordinary firewood, or on wood pellets (pellets) and are characterized by high efficiency;

Note!
The boilers are produced double-circuit, so that they can be used not only for heating, but also for the needs of hot water supply.

  • fuel tanks;
  • fuel pumps;
  • expansion tanks;
  • chimneys etc.

Overview of heating boilers

Given the cheapness of gas for the population in our country, gas-fired Kiturami heating boilers are especially popular. These devices are compact, high power, ease of maintenance and installation. There are several series of heating devices - 3 series marked World (Plus, 3000 and 5000), as well as Twin Alpha.

Features of boilers of the World 3000 and 5000 series

Particular attention is paid to the issue of heating efficiency - common feature all Kiturami heating devices, not only gas ones (efficiency exceeds 90%).

As for the World series, we can distinguish such features of their work as:

  • several modes of operation - for ease of adjustment, the modes are designated as "Absence", "Shower", etc.;
  • advanced safety block - gas analyzers instantly “feel” a gas leak and turn off the device;
  • turbocharging guarantees stable draft, combustion products are instantly drawn into the chimney;
  • enough power to heat a large area;

  • in steps of literally 1 ᵒС, you can adjust the temperature of hot water;
  • automation constantly monitors the condition of the main components of the heating circuit. For example, if there are power outages, the boiler will turn off, because the circulation pump will stop working, and the circulation of the coolant will be in jeopardy.
  • the self-diagnosis function looks curious. In the event of a malfunction by the illuminated digit, a person can determine the malfunction himself (of course, with the help of technical documentation).

The only fly in the ointment in this barrel of honey can be considered a slightly unusual design of the boiler. In particular, in the World series, a person unfamiliar with Kiturami products may be confused by the location of the air intake and exhaust of combustion products. When replacing the chimney with your own hands, this can be a small problem, but this drawback cannot be considered critical.

Celebrating Science - Twin Alpha Series

Devices of this series are considered the most modern and technologically advanced.

Among the features of Twin Alpha boilers it is worth noting:

  • extremely economical, when switching to standby mode, they consume about 1 W of energy;
  • the heat exchanger is not made of steel, but of pure copper and aluminum, the thermal conductivity of these metals is higher than that of steel.

The series includes 5 models differing in power and dimensions. So, heating boilers Kiturami Alpha 13R at its peak can produce a power of about 15.1 kW, which will be enough to heat a living area of ​​150 m2, while in hot water mode, water can be supplied at a rate of 8.6 l / min. The weight of this model is 26 kg.

The most powerful Alpha 30R model produces up to 34.8 kW and is able to heat a house with an area of ​​340 m2; in hot water mode, water is supplied at a rate of 20 l / min.

Note!
Despite the much greater power, the dimensions and weight of the boilers do not differ much.
So, the mentioned models of boilers differ only in width (the more powerful one is 5 cm wider) and weight (the Alpha 30R model weighs 3 kg more).
So there will be no problems with installation.

As for the cost, the Twin Alpha series is on average 10-12 thousand rubles cheaper than World3000.

For example, the Alpha 20R model costs about 30 thousand rubles, and the price of a device of the World3000 series comparable in terms of power is about 42 thousand rubles.

Installation Features

  • the weight of the wall model is 30 - 45 kg, so it is not recommended to place it on light partitions, the best option for installation, you can consider a load-bearing wall;
  • it is recommended to use a rubber gasket to reduce noise from possible vibration;
  • it is desirable that the installation site is not waterlogged.

Particular attention should be paid to the installation of the chimney; a coaxial chimney is used to remove combustion products. To facilitate the work, the use of telescopic chimneys is allowed.

The installation instructions for the pipe look like this:

  • when connecting individual elements, a sealing tape is necessarily used, and the tightness of the joint is achieved by tightening the connecting bolts;
  • in the case of a pipe outlet outside the wall, the manufacturer recommends limiting the maximum length to 2.5 m;

Note!
The pipe is given a slope of 3-5ᵒ in order to ensure the drainage of condensate.

  • as for the installation of a pipe through the roof, it is necessary that a free descent to the pipe be provided throughout the length of the pipe;
  • the horizontal section of the pipe in the section from the outlet of the boiler to the vertical section should not exceed 90 cm, otherwise the draft may deteriorate.

Summarizing

Heating boilers are popular not only in country houses, but also in the city, because heating system gives a lot of advantages over the centralized one. Kiturami boilers can be attributed to one of the most high-tech offers on the market, high efficiency, durability, the possibility of flexible regulation of work only contribute to the growth in popularity of this manufacturer's products.

The video shows how it works in detail. gas boiler Kiturami.

Every day more and more attention is drawn to Russian market heating technology, made in Korea, offering high quality, operational reliability and reasonable cost. An overview of boilers from Kiturami, owner reviews and a description of technical specifications will help you better understand the types and features of products, as well as make the right choice when buying.

The range of heating boilers from the Korean manufacturer Kiturami is grouped according to several characteristics:

  • type of installation - wall or floor;
  • type of energy source used - liquid, solid fuel, gas or combined;
  • the possibility of hot water supply - single or double-circuit;
  • combustion chamber - open or closed.

Description of gas, diesel, solid fuel and combined boilers Kiturami:

1. Korean liquid fuel heating boilers Kiturami Turbo have a set of features that can fully meet the needs of users:

  • The turbocyclone burner creates an aerodynamic flow, increasing efficiency.
  • Turbocharging contributes to the secondary afterburning of combustion products in a specially installed cylindrical chamber and their forced removal.
  • The security system includes sensors for combustion, temperature control and overheating, as well as the absence of coolant and fuel.
  • This series uses a new model chimney Kiturami, the efficiency of which is 2-3% higher than that of a similar class of boilers.

Turbo is one of the most economical boilers on the market with an average consumption of 8 l/day.

2. Wall double-circuit gas boilers Kiturami heating systems (World 3000, World 5000, World Plus and Twin Alpha) are distinguished by affordable cost and reliability. Built-in circulation pump and expansion tank facilitate installation, and a set of installed sensors performs safety control gas equipment.


Buying a World Plus-13R gas boiler will cost 32 thousand rubles, and the cost of Twin Alpha of the same capacity will be about 24,000. Structurally, the Kiturami TGB representative can be called an analogue of Turbo, but designed to work on liquefied gas. Repeated passage of combustion products in a steel three-way heat exchanger reduces noise and increases efficiency. The turbocyclone burner of a stationary heat generator of the KSOG series ensures stable operation of the boiler with pressure drops in the gas main, and also contributes to the secondary combustion of gases. The electronic control unit and the thermostat-regulator maintain the desired microclimate in the premises.

3. Kiturami biofuel heating boilers for home KRP series have the following features:

  • The feed auger doses the wood fuel automatically.
  • The complex design of the heat exchanger in the fire tube and water tubes allows increasing the efficiency up to 92%.
  • A circulation pump is built into the water tank of the heat generator for maximum heat transfer.
  • Multi-stage gas outlet avoids kickback flame.
  • The automatic cleaning system of the grate mechanically removes the "cakes" of sintered pellets, which prevents overspending.
  • Ignition of granules is carried out by a ceramic heating element of the Japanese company FKK.

The cost of a biofuel boiler Kiturami KRP-20 is about 140,000 rubles.

4. STS presents stationary combined boilers compact dimensions for installation even in small spaces. Design features distinguish this series with efficiency and a guarantee of long-term use (10 years):

  • Kiturami's turbo-cyclone burner and special swirl screen promote complete combustion of the fuel and reduce emissions carbon monoxide into the environment.
  • For the manufacture of the heat exchanger, an improved grade of stainless steel with a patented welding technology is used.
  • Advanced autodiagnostic system.

The Kiturami model range includes cast-iron boilers (KF series) designed for heating small spaces, the disadvantage of which is the need to periodically monitor the furnace and lay firewood. But the price of solid fuel boilers KF is two times lower than the pellet "brothers" - about 70,000 rubles.


Features of Kiturami products

Model KituramiDescriptionPrice, rub
Turbo-13R
  • diesel double-circuit boiler 15.1 kW;
  • Efficiency - 93.2%;
  • DHW - 8.4 l / min;
  • consumption - 1.5 l / hour.
27 200
Turbo-30R
  • liquid fuel heat generator with the possibility of replacing the burner with another type of fuel (gas);
  • power - 34.9 kW;
  • DHW flow - 20.7 l / min;
  • diesel consumption - 4.3 l / h.
38 690
KSOG-50R
  • stationary double-circuit heat generator with a capacity of 58.1 kW, sufficient to heat 580 m 2 of area;
  • copper DHW circuit;
  • Provides maximum DHW flow 33.3 l/min;
  • Efficiency - up to 92.9%.
96 840
World Plus-13R
  • gas wall-mounted boiler Kiturami 15.1 kW, designed for closed system heating;
  • two heat exchangers - copper and steel with storage;
  • Efficiency - 94.2%;
  • DHW - 8.7 l / min;
  • allows the use of antifreeze.
32 100
Twin Alpha-25R
  • wall-mounted gas boiler Kiturami with a power of up to 29 kW;
  • copper-aluminum heat exchanger;
  • Efficiency - 91.6-91.8% depending on the load;
  • lightweight expansion tank - 7 l;
  • DHW flow - 16.7 l / min.
27 800
STSO-13R
  • stationary diesel thermogenerator with the possibility of conversion to gas type fuel;
  • power - 16.9 kW;
  • double-circuit with closed camera combustion;
  • Efficiency - 90%;
  • Service life of Kiturami is more than 10 years.
27 520
KRP-20A
  • free-standing solid fuel boiler with forced ventilation;
  • thermal power - 24 kW;
  • Efficiency - 92.6%;
  • average consumption of granules (up to 32 mm long) - 5.53 kg / hour;
  • fuel capacity in the bunker - up to 160 kg.
139 900
KRP-50A
  • double-circuit pellet boiler Kiturami with a modulating burner;
  • power - 50 kW;
  • stainless steel heat exchanger;
  • bunker capacity - 300 kg.
169 900

What you need to know when choosing?

The wide assortment range offered by the Korean manufacturer is extensive, which makes it difficult for the average consumer to purchase. Therefore, the selection of heating equipment should be carried out according to the main characteristics of Kiturami:

  • Type of fuel used and efficiency. The choice of energy source for the operation of the units depends on the capabilities and desires of consumers.
  • Thermal power. A double-circuit thermogenerator must fully provide both space heating and water heating for household needs.
  • Mounting type. Wall mounted boilers are compact in size, but floor options greater power range.
  • Heating system. The selection of a specific model depends on the planned type of heating circuit - open or closed, as well as on the circulation of the coolant - in a natural way or forcibly.
  • The material of the heat exchanger affects the life of the boiler, its efficiency and cost.

The work of the Kiturami concern is aimed at the production of heating devices for biofuels and gas. But it was diesel-fueled equipment that made this manufacturer popular.

Advantages of diesel fuel installations:

  • Ease of use due to the ability to control any function using the remote control. The thermostat built into it determines the operating and temperature conditions. The operation of the boiler does not depend on the size and presence of draft, since the existing effect of turbocharging contributes to the forced direction of exhaust gases into the chimney;
  • High economic efficiency is achieved through aerodynamic flow during fuel combustion;
  • Possibility of self-configuration;
  • Year-round hot water supply;
  • The presence of a self-diagnosis system with information about the operation and malfunctions of the system;
  • Acceptable price;
  • Variety of lineup.

The only negative is the type of fuel, which creates a negative environmental situation when it is burned.


Equipment characteristics

  • The design, equipped with high-quality elements and blocks, is different from other brands. The heat exchanger is made of highly alloyed steel, superior in physical and technical qualities to other metals, which increases its cost, offset by high quality.
  • The equipment is made of copper, which does not react with water and increases its heat resistance. The presence of internal and external control units, which contributes to the regulation and control of the operating mode of the system from various places in the boiler room.
  • Coverage of the power range of floor-standing 2-loop units – from 10 to 35 kW, sufficient for heating 250-275 sq. m.
  • The dependence of the actual fuel consumption on personal settings. The nozzle is selected from the manufacturer for the actual power parameters.
  • Heating power, fuel consumption and its combustion mode are set independently. With power parameters up to 15 kW, the expected fuel consumption is 8 liters per day, while the burner will work with a certain frequency to create the optimal room temperature. By choosing the right heating mode and installing a variable temperature controller, you can significantly reduce fuel consumption.
  • Boilers for gas, diesel fuel, floor or mounted on the wall are mainly equipped with a combustion chamber closed type and forced gas exhaust system. steel or ceramic chimney coaxial, so that the supply of street air flow and gas removal are carried out at the same time.
  • It is possible to build a chimney with a slightly larger diameter - up to 120 mm. Reducing its size and cross section is unacceptable.

The lineup

The development of KSO models was originally carried out as gas-powered equipment. After changing the type of burner and slightly changing the monitoring and control system, it became possible to use other energy sources. The main fuel was diesel. The turbocyclone burner contributed to 100% fuel combustion and increased efficiency. The advantages of the model are simplicity of design, ease of maintenance and low price.


Biofuel boilers models KRM-30R and KRM-70R with changes made to their design, both diesel fuel and other solid fuels are used. The transition from one type of fuel to another is carried out quickly. System forced circulation improves the efficiency of the heater. These models differ only in power.

Model turbo 13r generates 13,000 kcal/hour of thermal energy or 15.1 kW, which is enough to heat 150 sq. m. heat costs for the preparation of hot water. With significant regular waste of boiling water, the thermal circuit power is lower.


Model turbo 17 has a thermal power parameter of 19.8 kW, sufficient to heat 180 square meters. m. To increase the limit of the upper performance threshold, nozzles on the burner are selected, which may affect fuel consumption.


Model turbo 21r with a capacity of 24.4 kW has an increased capacity of the DHW circuit. At the same time, the dimensions of the boiler remain unchanged.

Liquid fuel model turbo 30 r has a capacity of 34.9 kW, sufficient for heating 350 square meters. m. Equipped with flame-shaped burners, the fuel combustion mode is optimal. Due to the small number of nitrogen oxides, it is a highly environmentally friendly equipment.


Price

  • Turbo models 15-35 kW for heating 150-350 sq. m, weighing 52-85 kg - cost 28 thousand-37 thousand rubles;
  • STS models 17-35 kW for heating 160-350 sq. m, weighing 40-58 kg - cost 29 thousand-43 thousand rubles;
  • KSO models 58-465 kW for heating 580-4650 sq. m, weighing 93-750 kg - cost 75 thousand-428 thousand rubles.

Owner reviews

“In 2012, a Kiturami 17R boiler was purchased. Excellent purchase. He was supposed to work as an understudy for the Evan Epo-18 electric boiler, acting as the main heating system. Since an area of ​​150 sq. m, then the choice specifically fell on high-power equipment. In severe frosts, the main boiler cannot cope with maintaining the required temperature regime, it stops working due to a voltage drop in the network. Kiturami acts as a lifeguard by providing warmth and water.” Tambov, Arkady

“The Kiturami Turbo boiler is of interest in terms of hot water due to the presence of the SHOWER function, which is capable of delivering a small amount of hot water in a short period of time.” Sochi, Marina

“Wonderful equipment. No matter how many such systems have been installed, practically no one has any complaints. The whole of Siberia is warmed by them.” Yekaterinburg, Sergey

"Already cost this equipment able to interest. Spare parts are always in stock, the panels are unified.” Moscow, Konstantin

“We have our own claims to the boilers of this company. In my opinion, they are not entirely reliable. So we had to resort to repairs twice. Automation fails." St. Petersburg, Alexander

Installation and operation rules


In the presence of power surges, it is desirable to purchase a stabilizer to ensure the correct operation of the control and monitoring unit and safety from premature failure

The boilers are equipped with tanks for storing liquid fuel. These tanks can affect the performance of the equipment. Required correct installation this container, which must be exposed on all planes.

The tank must have a pipe for draining sediments and a fix bag. The container must be periodically emptied of fuel and cleaned; it is recommended to use only purified fuel.

Before starting the equipment, diesel fuel is initially filled into the tank, which must settle for at least half an hour. Only after that the unit is started and the operating modes are adjusted.

In the presence of power surges, it is desirable to purchase a stabilizer to ensure the correct operation of the control and monitoring unit and safety from premature failure.

To keep the boiler working you need:

  • Periodic mechanical cleaning.
  • Continuous monitoring of equipment performance and checking of components and parts for their leakage.

Self-installation of diesel boilers is possible with a careful study of the schemes and recommendations of the manufacturer. However, there are many operations that require the presence of highly qualified specialists, so that later the equipment does not have to be repaired. The instructions for the exact order and principle of installation and the electrical installation diagram serve to illustrate the implementation of these works.

Kiturami boilers are economical option with a long service life. The reason for the premature repair is untimely service or low-quality fuel filling.

Error codes:

Reasons for no ignition - error code "01":

  • Jamming of the screw limiting the fuel level. It is necessary to replace the locking element or check the injection motor;
  • Injection motor failure– it will be necessary to check the performance of the motor;
  • Lack of fuel supply- you will need to check its level;
  • third party item in a screw gate;
  • Photosensor failure- it needs to be checked for functionality.

  • Diesel single-circuit and dual circuit models, the latter are more convenient, but more expensive. Choosing the first option, you need to purchase a boiler and other appliances and fixtures, but its cost will still be lower.
  • It is worth paying attention to the depth of the fuel intake according to the criterion for determining the deep location of the fuel and the fuel tank. According to fire safety, fuel tanks must be dug into the ground to an appropriate depth. With low power, the depth of the fence is higher.
  • The cost of installing the equipment will include the price of the heater, its installation, start-up and adjustment works, maintenance and spare parts during its repair.

Even at the design stage of heating in the house, one has to operate with generalized technical specifications boiler, but in the end you still need to go to the store and choose a very specific model from the huge range on the market.

It will be useful to find out in more detail what the Kiturami diesel boiler is, what models are in the line, and how they can be better than other offers on the market.

Features of Kiturami boilers

Kiturami is a South Korean company with more than half a century of experience in the design and manufacture of heating boilers and related equipment.

During this time, the company has become one of the leaders in the domestic Korean market, and has also found an extensive market in North America and nearby Asian countries. In our country, Kiturami boilers have been officially distributed for at least ten years and have already shown themselves on the good side.

The main emphasis in the promotion of boilers is on the introduction innovative technologies and in particular our own developments, which have no analogues from other manufacturers or determine the narrow specifics of the equipment operation.

Diesel boilers, by definition, are not considered as the main model range for a wide range of applications. In terms of economic feasibility, they are inferior to gas, electric and even solid-state boilers. However, they are still in demand among consumers in view of a number of reasons why liquid fuels are becoming preferable.


In remote areas of residence, where there is no stable connection to the power grid, there is no gasification, the issue of fuel availability becomes acute. At the same time, the heating of the house should, by definition, work smoothly throughout the season. If for many countries such situations are rather an exception to the rule, then for us, on the contrary, they are commonplace, the cause of which is the vast expanses separating settlements.

Diesel fuel, unlike gas, is easier to transport and store with minimal risks to life and the environment. Unlike solid fuel boilers, when burned, diesel fuel gives uniform heating and greater degree control over the use of resources. And finally, the design of the diesel boiler and in particular the burner does not limit the use of other heat sources.

With minimal modifications, the diesel burner can be replaced for the use of blue fuel, and boilers equipped with an extensive combustion chamber and a grate, can quickly switch to charcoal, wood or pellets.

Diesel boilers Kiturami are highly technological and are a perfectly balanced equipment for the use of diesel fuel as a heat source, and at the same time they are excellent for the above types of conversion to work on gas or solid fuel. So constructive and functional flexibility is the first significant advantage.

Kiturami boilers often use their own designs and unique layouts. On the one hand, this reduces the maintainability of heating equipment, but on the other hand, it ensures the highest efficiency of the boiler and balanced operation while observing simple and transparent operating rules. This is the second significant reason to pay attention to diesel boilers from South Korea.

The last advantage is the cost of boiler equipment. Even taking into account the high performance and proven quality of the boilers, their cost does not exceed the average on the market among similar offers.

So it turns out that Kiturami boilers have three features: a balanced design, high efficiency and affordable price.


Kiturami boiler device

Specifications

Operational characteristics, dimensions and parameters of the Turbo series boilers are presented in the table below. It is clearly seen that a series of floor standing diesel boilers covers a power range from 10 to 35 kW, which is quite enough for heating houses up to 250-275 square meters. Part of the heat will go to the preparation of hot water, which must be taken into account in the calculations.

All Kuturami boilers are double-circuit and heat exchangers, by the way, are ideally designed specifically for these tasks.

Boiler modelUnit ismTURBO-9RTURBO-13RTURBO-17RTURBO-21RTURBO-30R
Powerkcal/hour9000 13000 17000 21000 30000
PowerkW10,5 15,1 19,8 24,4 34,9
Fuel consumptionliter/hour1.13÷1.51.6÷1.971.87÷2.152.28÷2.803.75÷4.30
efficiency% 92 92 92.2 92.4 91.8
DHW consumption∆t=25ºC6,0 9,7 11,3 14,0 23,3
∆t=40ºC3,8 6,1 7,1 8,7 14,6
Heating supply and returnmm25 25 25 25 25
Hot water inlet/outletmm15 15 15 15 15
Chimney diametermm80
Power supplyV/Hz220/50(60)
Power consumptionTue80 160
External sizew×d×h325×600×835365×650×930
The weightkg60 79 85 85 85

Fuel consumption

Fuel consumption is specified in the table with technical requirements. However, please note that the actual flow rate depends on individual settings. Under the actual power required for heating the house, the appropriate nozzle is selected from the set proposed by the manufacturer.

The thermal power, fuel consumption and fuel combustion mode are set. The parameter indicated in the table displays factory presets sufficient to ensure proper performance if only high-quality fuel is used, more often it means diesel fuel already with winter additives that do not allow it to thicken or stand out paraffin in excess.

In a real situation, for a boiler model with a power of up to 15 kW, one can expect fuel consumption at the level of 8 liters per day taking into account the frequency of the burner and the optimal temperature in the house. However, this is not the limit.

The right approach to choosing the heating mode, as well as installing a controller with a variable temperature regime, for example, depending on the time of day and day of the week, can reduce consumption even more.

Chimney

Boilers Kuturami, gas, diesel, floor or wall-mounted, for the most part, are equipped with a closed combustion chamber and, accordingly, a forced exhaust gas system. The Turbo series, which we are in this moment consider.


Chimney installation diagram

The chimney for boilers is used coaxial for the simultaneous supply of fresh air from the street and the removal of exhaust gases. Since the exhaust temperature after passing through the heat exchangers is no longer high, the requirements for the heat resistance of the chimney are reduced, and the list of acceptable materials is expanding.

In the best case, a steel coaxial chimney is still used, however, a ceramic chimney can be effectively used in the same quality. vertical chimney with a group of internal separate channels for air supply, exhaust gases from the combustion chamber and ventilation of the boiler room.

The size of the chimney is strictly specified in the boiler specification and operating instructions. For the entire Turbo series, this is 80 mm.

It is possible, if desired, to make a chimney of a slightly larger diameter, but not more than 50% in excess of the specified value, that is, up to 120 mm.

In no case can the size and cross section be reduced. Even though the removal of combustion products is forced, the resistance of the chimney will greatly affect the combustion mode and the quality of the fuel burnout.

turbo 13r

The model number of the boiler corresponds to the amount of heat generated per hour - 13000 kcal/hour. In terms of the usual kilowatts, the values ​​\u200b\u200bare obtained are 15.1 kW.

The declared power is enough to heat a house up to 150 m2. Naturally, one should take into account the heat costs for the preparation of hot water supply. If a significant consumption of hot water is predicted, moreover, regularly, then the heat output for the heating circuit will naturally be lower.

Reliability and balanced operation, combined with the affordable cost of the boiler, gives clear advantage in the case of using several boilers simultaneously in one building, for example, when dividing the heating circuit for each floor separately or when covering a large area in two more wings, directions.

turbo 17


Boiler Kiturami turbo

The thermal power already reaches 19.8 kW, which is enough to cover the heating of a house up to 180 m2. It is possible to reasonably increase the upper performance threshold by selecting the appropriate nozzle on the burner, however, this will affect fuel consumption.

This approach allows you to solve the problem with increased DHW consumption so that without extra costs do not hesitate to use hot water even in the most severe frosts.

turbo 21r

With a further increase in power, there is a model with a declared capacity of 24.4 kW, along with this, the performance of the DHW circuit increases significantly. It should be noted that the dimensions of the boiler do not change compared to the younger models.

turbo 30r

The most powerful model in the Kiturami line of liquid fuel boilers. Performance at the level of 34.9 kW makes it possible to heat a room up to 350 m2, but at the same time the cost of the boiler in retail is approximately 45-46 thousand rubles., which is certainly an attractive option.

As with the entire range of boilers, burners with a unique flame shape and optimal mode fuel combustion.

The minimum amount of nitrogen oxides is recorded in the exhaust, which indicates the high environmental friendliness of the equipment.

Setting

It is better to entrust the initial start-up and configuration of Kiturami boilers to a specialist who can correctly determine the optimal operating mode, select the desired type of nozzle and calibrate fuel consumption depending on its characteristics and even the connection method and location of the fuel tank.

Nozzle for diesel boiler

For self installation supplied with the boiler detailed instructions, according to which it is possible to determine the operating mode closest to the design value.

The main thing is to follow the sequence of actions defined in the technical documentation and visual aids for putting the equipment into operation.

It is necessary to adjust and adjust the boiler settings not only at the first start-up, but also during maintenance before each new season and for switching to summer mode, in which only the DHW circuit will be used.

Faults

Kuturami boiler equipment is equipped with a full-fledged self-diagnosis system built on the work of a number of sensors. The controller is able to evaluate the condition of the equipment, as well as the current mode of operation, and respond to any deviations or problems that arise during operation.

In any emergency situation, the main action determined by the boiler controller is to stop the burner in order to prevent significant consequences.

A well-developed self-diagnostic algorithm allows you to identify the problem and indicate the error code on the display so that the user can take action as quickly as possible necessary actions for repair and refurbishment.

In list frequent breakdowns diesel boilers Kiturami:

  • No ignition (error code 01);
  • Does not start, no messages on the display.;
  • Coolant leakage (depressurization of the heat exchanger or one of the pipeline connections);
  • The flame goes out periodically with an emergency stop of the boiler;
  • There is no draft, the operation of the boiler is accompanied by the flow of smoke and exhaust into the room.

Error 01 and solution

If error code 01 appears on the boiler display screen, it means that for some reason the fuel did not ignite, there is no torch, the controller forcibly stops the fuel supply, issues an error message, and signals the problem to the user.

Solving the problem requires the exact implementation of a procedure that can identify the source of the problem and eliminate the obstacle in the boiler as efficiently as possible.

Briefly, the procedure looks like this:


Quite often, the fuel-air mixture is supplied under too much pressure into the chamber and therefore does not have time to ignite from the electrode. The problem is solved even at the 5th step of the algorithm by adjusting the air damper, which causes a mixture with a changed concentration to enter the chamber.

Doesn't start

The most unpleasant situation is when the boiler simply does not turn on. There are no signals on the display, and accordingly there is no error code by which it would be possible to determine the malfunction.

In such a situation, it would be adequate to call a service center specialist who will be able to understand the situation and issue the correct verdict, as well as determine the repair procedure. On your own, you can only check the presence of voltage in the network, as well as the fuses in the boiler.

leak

Most often, a leak means that a gasket seal has been damaged in some connection of the pipeline inside the boiler. It is enough to inspect the equipment and determine the place of leakage, replace the gasket.

The heat exchanger in Kiturami boilers is made of alloyed steel and copper, so it does not leak without obvious errors in the selection of the coolant or mechanical damage.

Burner goes out intermittently

The most common cause is a burner setting failure. It is important to adjust it in terms of power and use a gas analyzer to determine optimal ratio air/fuel for proper combustion. Such work cannot be done on your own, so it is better to contact the service center.

No draft, smoke and exhaust enters the room

Most likely the burner fan is not working for some reason. It is important first of all to check that the impeller is intact and scrolls normally.

It is possible that debris has accumulated inside the fan, or the impeller shaft is jammed. Next, the electrical part and the control unit are checked.

Heating at home winter period is a top priority for every homeowner today. Most of all, this issue is relevant for owners of suburban housing. And although modern gas boilers are as advanced as possible, they are inaccessible to many people due to the constant increase in the price of this type of fuel.

So a large number of consumers choose others alternative options, one of which is a diesel boiler Kiturami. Although they are not new on the market, they have not lost their popularity at all. They are able to provide high-quality heating in the house.

Today Kiturami is a well-known South Korean concern, one of the most major manufacturers heating equipment. Repeatedly, the boilers of this company were awarded diplomas for reliability and technical perfection, and due to the presence of certificates that meet all international standards, the Kiturami diesel heating boiler is exported to almost all countries.

What is the peculiarity of heating equipment from Kiturami?

The Kiturami concern is engaged in the production different types heating equipment, which includes biofuel and gas installations. But it was Kiturami's diesel heating equipment that brought the concern such great fame and a high rating. The name diesel itself speaks of the type of fuel on which it runs.

Rice. one

The most popular model in the line of this manufacturer is the Kiturami Turbo 17 diesel boiler, the purpose of which is hot water supply and heating of industrial and residential premises. Boilers from the manufacturer Kiturami are very convenient for use in country houses, when the need for hot water does not arise daily, and heating is required only during the presence of the owners there. Moreover, at correct operation repair of such equipment is very rarely necessary.

The main advantages of Kiturami diesel heating equipment include:

  • the diesel copper of Kiturami is convenient in operation. The control panel allows you to set any control function. Kiturami's work on coolant and room temperature controlled by a thermostat built into the remote control. The boilers are independent of the size of the chimney and the presence of draft due to the presence of a turbo blowing effect, which forcibly sends the exhaust gases to the chimney;
  • diesel Kiturami is highly economical. Due to the aerodynamic flow in the combustion chamber, maximum efficiency in the amount of fuel consumed;
  • setting up the equipment is absolutely simple, and you can do it yourself;
  • all year round the house has hot water. Boilers of the Kiturami brand are also used at a time when the room is not heated;
  • The Kiturami diesel boiler has a self-diagnosis system that informs on the display about its operation and the malfunctions that have occurred, showing the real state of the system. If you constantly monitor the display readings, then the need for repairs will be minimal.

Features of Kiturami in operation

The diesel heating unit represented by the Kiturami concern differs significantly from other brands in its characteristics, both in terms of the method of maintenance and the need for repair. Only high alloy steel is used to manufacture the heat exchanger.


Rice. 2

Kiturami brand boilers are made of copper, which is highly resistant to water. If we talk about the price, then in comparison with stainless steel, copper is much cheaper, and, accordingly, a diesel boiler costs accordingly. In addition, copper significantly increases the heat resistance of equipment.

The quality of the Kiturami Turbo depends on how correctly placed the tanks in which the fuel is stored. Here it is necessary to correctly place the tank and expose it in three surfaces. It is imperative to take into account that a drain is provided in the sedimentation tank. The Turbo tank should be cleaned regularly and the sediments should be drained, and the fuel should only be filled into the diesel mechanism in a cleaned form. Such handling contributes to trouble-free operation, and the need for repairs is not needed.

When the Kiturami diesel boiler is filled with fuel, the instruction says that you need to wait half an hour until it settles. Only after this, the Turbo diesel boiler can be started and the necessary modes can be adjusted. It is also advisable to use a stabilizer to avoid repairs from sudden changes in mains voltage. It will ensure the stable operation of the control unit, as well as protect the heating unit from premature repairs.

In order for the Kiturami diesel heating boiler to work smoothly during operation, the following is necessary:

  • the boiler setting must be carried out correctly and correctly, then the need for repairs will be minimal;
  • a diesel boiler requires the systematic implementation of its mechanical cleaning in order to protect it from premature repairs;
  • Turbo should regularly monitor the operation of all its connections and assemblies for leaks;
  • the performance of the equipment must be checked regularly so that it is not necessary to prematurely repair Kiturami diesel boilers.

Equipment installation and connection

All the requirements for connecting Kiturami are absolutely not difficult to fulfill on your own. You can install the Kiturami diesel boiler without the help of specialists, it is enough to carefully study the scheme and recommendations of the manufacturer. But at the same time there are many operations that require the presence skilled craftsmen so that later wrong actions avoid repair.

For those people who for the first time have to assemble heating equipment Kiturami diesel boilers, the instructions and installation diagram will serve as good example carrying out such work. It is very important that the Kiturami Turbo is connected using electrical circuit boiler and all recommendations for connecting to the power supply were clearly followed.

Who is not sure that he can independently perform all the work on which the setting of the Kiturami diesel boiler directly depends, it is best to involve specialists, and thus avoid possible errors and early repair.

The Kiturami diesel boiler requires an extremely precise order and principle of its installation, since an incorrect connection is most often the cause of equipment failure and it becomes necessary to carry out expensive repairs of Kiturami diesel boilers.

Description of Kiturami malfunctions and repair

The Kiturami diesel boiler belongs to the economy option and has a rather long service life. But there are situations when the boilers fail prematurely. The reason for the need to repair Kiturami is their untimely service or the use of poor quality fuel.

A simple repair of Turbo boilers can be carried out independently, but it is more rational to contact service organizations in case of malfunctions.

Rice. 3 Installed boiler Kiturami

Below are the main error codes that the Kiturami Turbo 17 diesel boiler is most often exposed to:

  • when the lights on the display flash "01", "02" or "03" - it means that there are problems in the flame detector and ignition does not occur. The Turbo boiler in this case should be restarted according to the instructions;
  • error "04" indicates that the water temperature sensor is faulty in the Kiturami heating system, and repair in this case becomes inevitable;
  • error "08" warns that the route between the boiler and temperature sensor very long or a wire break has occurred in some place. Repairs will be required to identify the immediate cause of the failure;
  • error "95" means too low pressure in the heating circuit. The Turbo boiler must be energized and the entire heating system must be examined for the possibility of leaks;
  • error "96" - the mechanism that protects the Turbo system from overheating has worked;
  • error "98" - indicates that there is a lack of fuel in the supply line.

Of all the errors described above, “01” flashes most often on the display, but this does not pose a great danger to the operation of the equipment. The diesel boiler Kiturami Turbo 17 is characterized by maximum efficiency. Thanks to the control panel, the functionality of the boiler control is achieved and room heating is possible in any temperature regime.

In Turbo it is possible to regulate temperature parameters step by step from 45 to 75°С. All information about the operation of the diesel Kiturami Turbo on the thermostat screen is displayed by the self-diagnosis mechanism.

Most often, the Kiturami diesel boiler gives error 01. This happens when there is no stable ignition in the Turbo.

The reasons may be as follows:

  • when the screw jams, which serves as a fuel level limiter. The repair consists in the need to replace the locking element or check the injection motor;
  • when the blower motor fails. Need to check working condition Kiturami motor. If the motor is faulty, then the repair consists in replacing it with a new one;
  • when there is a lack of incoming fuel, then its level should be checked in the tank, in this case repairs will not be needed;
  • when a third-party object accidentally appears in the screw gate, then it must be removed during the repair process;
  • when the photosensor fails, the Turbo repair consists in checking this element for its operability.

When the error code “01” periodically appears on the display, then in such cases it is necessary to seek help from the relevant specialists in order to avoid major costly repairs.

Holding regular prevention and Kiturami repair is a guarantee that Turbo boilers will work efficiently and reliably. If irreparable damage occurs in the diesel boiler during the warranty period, then it is repaired without the need to pay for such work.

The Kiturami Turbo diesel boiler has excellent performance, but it must always be remembered that non-compliance established scheme installations, correct setting and elementary rules for handling it in many cases ends with a total repair. When all requirements for use and operation are met, modern technologies for the production of Kiturami heating equipment guarantee each user stable operation of the boiler without the need for repair and a long service life.

Loading...