Gas boiler Neva Lux error 03. Heating systems for country and country houses. Boilers, geysers, water heaters - Repair, service, operation. Recommendations for assembly and installation. Codes of errors and malfunctions of boilers Neva Lux

This article contains all possible malfunctions and options for their elimination, as well as error codes for Neva Lux boilers. All information is read in the following order: code - name - possible malfunction. If you have any additional questions, please leave them in the comments to this article.

If you are not 100% sure what exactly the problem is and that you can solve it, immediately contact service center for troubleshooting and troubleshooting.

Check price and buy heating equipment and related products you can from us. Write, call and come to one of the stores in your city. Delivery across all territory of the Russian Federation and the CIS countries.

If the Neva Lux boiler has a failure or incorrect operation of any of its systems, then it displays the corresponding error code on the display. This makes it easy to find and fix the damage.

Error code 01 - Ignition error

This code means that the boiler has a problem with ignition. In this case, the device does not start up. Possible reasons:

  1. There is no gas supply. It is required to check the shut-off valve on the gas pipeline. If everything is in order there, then it is necessary to measure the pressure in the cylinder, provided that the unit runs on liquefied gas.
  2. The spark plug broke. Not repairable, needs to be replaced.
  3. Problems with the electrical circuit of the spark plug. To eliminate it, you need to check the contacts and the circuit itself.
  4. Incorrect gap between spark plug and burner section set. The gap should be adjusted according to the instructions. It must be 5 mm with a tolerance of no more than 0.5 mm.
  5. The spark coming from the spark plug electrode jumps to the shell of the combustion chamber. To eliminate it, you need to move the shell away by bending it together with the installation of the candle.
  6. The spark plug was covered with dirt. Needs to be cleaned and degreased.
  7. Breakage of the ionization candle. Replacement required.
  8. Problems with the electrical circuit of the ionization candle. Checking the circuit itself and the contacts is required.
  9. Breakdown of the ignition transformer. Install a new one.
  10. The electrical circuit of the ignition transformer is damaged. Check the circuit itself and the contacts.
  11. The burner block is dirty. Clean up.
  12. Gas regulator circuit problem. Check circuit and contacts.
  13. Defective gas regulator. Replace it.
  14. Thermal relay failure. During normal operation, it should open at a temperature of 90 degrees. Replacement required.
  15. Thermal relay electrical circuit damaged. Check the electrical circuit of the heating sensor and its contacts.

Error code 02 - The water temperature has exceeded the allowable value

This code means that the water temperature has exceeded the allowable value. The BaltGaz boiler is standing due to an accident. Possible causes and elimination algorithm:

  1. There is no flow in the heating system due to severe clogging. Cleaning required.
  2. Thermostat failure. Normally, it should open at a temperature of 90 degrees. Its replacement is required.
  3. There is air in the heating system. Discard it through the bleed valve.
  4. Strong contamination of the filter located in the heating system. It needs cleaning.
  5. Valve and bypass problems. Most likely, it is incorrectly installed or broken. Check that it is installed according to the instructions, replace if necessary.
  6. Pump failure. Replace.
  7. Defective air valve. Replacement required.
  8. Failure of the pump relay located on the electronic board. The board needs to be replaced.
  9. Damage to the gas supply regulator. Install a new one.
  10. Incorrect gas regulator setting. Carry out the setup according to the instructions.
  11. The electrical circuit of the overheat sensor is damaged. Check the contacts and the circuit itself.

Error code 03 - No traction

This code reports a lack of traction. The device has been stopped due to an accident. Possible causes and solutions:

  1. Exhaust gases are not removed, respectively, the chimney may be clogged. Clean it up.
  2. Poor air supply to the furnace. Clean the air intake duct.
  3. There is no tightness of the pressure switch tubes. Carry out a replacement.
  4. Problems in the electrical circuit of the pressure switch. Checking the contacts and circuit is required.
  5. Pressure switch failure. During normal operation, the pressure switch contacts close if the differential pressure is equal to or greater than 130 pascals. Replacement required.
  6. Condensation has accumulated in the pressure switch tubes. Remove condensate.
  7. Fan electrical circuit damaged. Check circuit and contacts.
  8. Fan failure. Repair or replace.

Error code 04 - Insufficient water pressure in the heating circuit

It indicates that the water pressure in the heating circuit is insufficient. The Neva Lux boiler was stopped due to an accident. Reasons and ways to eliminate them:

  1. The water pressure in the heating system is below normal. Top up the heating circuit with water up to the indication required by the manufacturer on the manometer.
  2. Airiness of the system. Discard it through the air outlet cock.
  3. Damage to the water pressure sensor located in the heating circuit. The sensor needs to be replaced.
  4. Pump failure or bleed valve. Repair or replace.
  5. The electrical circuit between the pressure sensor and the electronic board is damaged. Check the contacts of the connectors in the control unit, as well as the contacts on the sensor. Check the electrical circuit for continuity.

Error code 05 - Error of the temperature sensor responsible for heating

Problem with the temperature sensor responsible for heating. The unit has been stopped due to an accident. Reasons and ways to eliminate them:

  1. Broken temperature sensor. Its replacement is required.
  2. There is a problem with the electrical circuit between the temperature sensor and the electronic board. Check circuit and contacts.

Error code 06 - DHW temperature sensor error

Indicates that the DHW temperature sensor is faulty. The operation of the BaltGaz boiler is carried out only for heating. Possible causes and their elimination:

  1. Damage to the DHW temperature sensor. Replace it.
  2. The electrical circuit between the sensor and the board is damaged. Check her and contacts.

Error code 07 - Error in the operation of the gas regulator modulator coil

Incorrect operation or breakdown of the gas supply regulator modulator coil. The device has been stopped due to an accident. Possible causes and their elimination:

  1. Breakage of the gas supply regulator modulator coil. Normally, its resistance should be 80 ohms. When broken, it needs to be replaced.
  2. There is no contact between the modulator coil and the electronic board. Check the electrical circuit and the contacts themselves.

Existing breakdowns in which errors do not appear on the device

If the electronic display of the Neva heating boiler does not show an error code, but the equipment does not turn on, pops are heard, there is a smell of gas, etc., then this may also indicate an existing breakdown of the system. Inspect the boiler, fix the problem, find its description in this article below and fix the problem in time.

It is impossible to turn on the Neva Lux boiler

  1. There is no electricity in the network. Contact your electricity supplier.
  2. The fuse on the board has blown. Its replacement is required.
  3. Moisture has entered the circuit board. To fix, try drying the board with slightly warm air, or remove the board and place it in a dry place for a few days. warm room. It is important that the water completely evaporates.
  4. The electronic board may be damaged. AT this case the reset button won't help. To fix it, you need to disconnect the device from the network and try to turn it on again. If this does not fix the problem, then a new board should be installed.

Pops are heard in the burner

  1. The settings for the minimum gas pressure and ignition power are set incorrectly. Re-adjustment of these parameters is required.
  2. Too poor air supply to the burner. To eliminate it, it is necessary to clean the pipe or channel through which air is supplied.
  3. Problems with a spark from the spark plug electrode. It slips to the edge of the burner section or to the shell of the combustion chamber. To eliminate it, it is necessary to slightly bend the spark plug, or, conversely, move the shell away from the combustion chamber. In this way, you will ensure that a spark enters the area of ​​\u200b\u200bthe nozzle holes of the burner section.
  4. The burner block may be dirty. It needs cleaning.

When the Neva Lux boiler is operating, there is a strong smell of gas

  1. Maybe there is a leak somewhere and the gas is leaking. Check your circuit for leaks and locate any leaks in the room. Eliminate.
  2. Faucets do not hot water or very weak pressure. Pressure cold water supplied to the DHW circuit is not enough for correct operation. Contact your cold water supplier.
  3. The water filter is heavily soiled. It needs cleaning.
  4. The filter is on the DHW line. In taps, the water temperature is much higher than the set temperature. To eliminate this problem, it is necessary to increase the amount of water passing through the DHW circuit. You can also dilute hot water with cold water. However, the flow rate cannot be reduced.

Too low water flow through the DHW

Zoom it in.

The device works fine in DHW mode, but does not work for heating the house

  1. No room thermostat jumper. Install it.
  2. Breakage of the room thermostat jumper, which closes the contacts. Replacement required.
  3. The room thermostat itself may be damaged. Replace.

The system is supplied with a temperature lower than the set temperature.

The sensor for controlling the temperature of the water supplied to the heating is broken. Descale this sensor first. This is true if a submersible sensor is installed. Or do a replacement.

When the device is in pause mode, it shows the symbol “—” on the display.

It does not respond to any buttons. The voltage supplied to the device has become more than 190 - 250 volts. To eliminate this malfunction, supply voltage to the acceptable limits. Every 30 seconds the unit tries to start in automatic mode and it will do so until the problem is solved.

Codes of errors and malfunctions of boilers Neva Lux

Stopping the operation of the Neva Lux boiler, caused by a failure or malfunction of any of its systems, is accompanied by the display of the corresponding error code on the control panel display, which makes it easier to detect a malfunction.

error codes, possible reasons and troubleshooting methods

Error 01- Faults related to unsuccessful ignition. The boiler is not working.

Gas supply problems - Open the shut-off valve on the gas pipeline, or check the pressure in the cylinder (liquefied gas.)

Spark plug defective - Replace spark plug.

Faulty spark plug circuit - Check circuit and connections.

Incorrect gap between spark plug and burner section - Set gap (5+0.5 mm).

A spark from the spark plug electrode jumps onto the combustion chamber shell - Bend the combustion chamber shell at the place where the spark plug is installed.

Spark plug dirty - Wipe the spark plug free of dust and degrease.

Faulty ionization plug - Replace the plug.

The ionization plug circuit is broken - Check the circuit and contacts.

Incorrect gap between ionization plug and burner section - Set gap (3+0.5 mm).

Faulty ignition transformer - Replace the ignition transformer of the Neva Lux boiler.

The electrical circuit of the ignition transformer is broken - Check the electrical circuit and contacts.

Burner block clogged - Clean burner block.

Disrupted electrical circuits of the gas regulator - Check the electrical circuits and contacts.

Error 02- Water overheating. The boiler is not working.

Clogged heating system - Clean the heating system.

Thermal relay defective (normally closed at temperatures up to 90 °C) - Replace the thermal relay.

The filter in the heating system is clogged - Clean the filter.

Faulty or incorrectly installed, bypass valve - Check the correct installation of the bypass valve parts and replace it if necessary.

Defective pump or vent valve - Replace pump or vent valve.

Faulty pump relay on the electronic board - Replace the electronic board.

Gas regulator not working - Replace gas regulator.

Gas regulator not set - Adjust gas regulator.

The electrical circuit of the thermal relay (overheating sensor) is broken - Check the electrical circuit and contacts.

Error 03- Lack of traction. The Neva Lux boiler is not working.

Clogged chimney or air intake duct - Find out the cause of the blockage and eliminate it.

The tightness of the pressure switch tubes is broken - Replace the tubes.

Violation of the electrical circuit of the pressure switch - Check the electrical circuit and contacts.

The pressure switch is faulty (the contacts of the pressure switch must close at a pressure drop of 130 Pa or more) - Replace the pressure switch.

Condensation in pressure switch tubes - Remove condensate from pressure switch tubes.

Fan circuit failure - Check circuit and connections.

Faulty fan - Replace fan.

Error 04- Insufficient water pressure in the heating circuit. The boiler is not working.

Reduced water pressure in the heating circuit - Bring the water pressure in the heating circuit to the recommended value.

Airlock in the heating system - Open the vent valve.

Faulty water pressure sensor in the heating circuit - Replace the sensor.

Defective pump or vent valve - Replace pump or vent valve.

The electrical circuit between the pressure sensor and the electronic board is broken - Check the contacts of the connectors in the control unit and on the sensor and the electrical circuit of the sensor.

Error 05- Failure of the heating circuit temperature sensor. The boiler is not working.

Heating circuit temperature sensor defective - Replace the heating circuit temperature sensor.

The electrical circuit "temperature sensor - electronic board" is broken - Check the electrical circuit and contacts.

Error 06- Failure of the DHW temperature sensor. The Neva Lux boiler only works in heating mode.

Faulty DHW temperature sensor - Replace the DHW temperature sensor.

The electrical circuit between the DHW temperature sensor and the electronic board is broken - Check the electrical circuit and contacts.

Error 07- Failure of the gas regulator modulator coil. The boiler is not working.

Breakage of the gas supply regulator modulator coil - Replace the gas supply regulator (modulator coil resistance 80 ohms).

The electrical circuit "modulator coil - electronic board" is broken - Check the electrical circuit and contacts.

Malfunctions of Neva Lux boilers without an error code

Boiler Neva Lux does not turn on

No electricity - Contact the electricity company.

Fuse blown - Replace the fuse on the board.

Water ingress on the electronic board - Dry the board with warm air or leave it for two days in a dry place to completely evaporate the water.

Electronic board failure (RESET does not help) - Turn off the power and turn on the boiler again or replace the electronic board.

Pops in the burner

Minimum gas pressure and ignition power set incorrectly - Adjust the minimum gas pressure and ignition power.

Insufficient air supply - Clean pipe or air intake duct.

A spark from the spark plug electrode jumps to the edge of the burner section or to the shell of the combustion chamber - Bend the spark plug or bend the shell of the combustion chamber, ensuring that the spark jumps into the area of ​​the holes in the nozzle of the burner section.

Dirty burner block - Clean the burner block.

The smell of gas

Gas leakage - Check the entire gas circuit for leaks, repair gas leakage.

Little or no hot water output

Insufficient water pressure at the inlet to the hot water supply - Contact the housing and communal services.

Clogged water filter - Clean the filter on the DHW line.

Clogged heat exchanger - Clean the heat exchanger.

Hot water temperature not maintained (too high)

High inlet water temperature - Increase the flow of water through the DHW circuit or dilute hot water with cold water without reducing the flow through the DHW circuit.

Small water flow through the DHW circuit - Increase the water flow through the DHW circuit.

Boiler Neva Lux does not work in heating mode (but works in DHW mode)

Room thermostat jumper missing - Install room thermostat jumper.

Faulty room thermostat jumper connecting the contacts - Replace the room thermostat jumper.

Room thermostat defective (if thermostat is installed) - Replace room thermostat.

The water temperature at the inlet to the heating system is below the set value

The temperature sensor of the heating circuit is defective - Clean the temperature sensor from scale (in case of using an immersion temperature sensor), or replace the temperature sensor.

The boiler is in standby mode, the symbol “- -” is displayed on the display and the boiler does not respond to pressing the control buttons

The supply voltage has gone beyond 190 ÷ 250 V - Restore the supply voltage within 190 ÷ 250 V. After 30 seconds, the boiler will automatically start in the mode in which it was before the voltage went beyond 190 ÷ 250 V.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Gas wall boilers Buderus
Models Logamax U042, U044, GB072, GB172. with open and closed camera combustion. Methods of repair and service, adjustment of operating parameters. Maintenance recommendations.
Gas heating boilers Vaillant
Models: floor-standing Atmovit exclusiv, wall-mounted condensing Ecotec plus. Service, Maintenance, functional component settings. Hydraulic schemes.
Gas wall boilers Ariston
Models Clas, Clas Evo, Genus. Recommendations for repair, maintenance and service. Elimination of errors and malfunctions. Methods of tuning and adjustment.
gas boilers Immergas
Models Eolo Star, Eolo Mini, Nike Star, Nike Mini, Mitos. Repairs and adjustments. Installation, installation and connection. Working mode settings and additional equipment.
Kentatsu Furst boilers
wall models nobby smart. Condensing Smart Condens. Floor Sigma, Kobold. Solid fuel Elegant, Vulkan. Faults and error codes. Description and characteristics.


Neva Lux boiler errors and their meanings

Error 01 (E2)- Fault due to unsuccessful ignition or overheating of the coolant. The boiler is not functioning.

Code 01 for models Neva Lux 7023, 7224, 8224. Code E2 - Neva Lux 8023, 8029.

Burner blockage. Clean burner and nozzles. The ignition electrode is defective, its electrical circuit is broken, the gap between the ignition electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (4-5 mm). Replace ignition electrode. Ignition transformer malfunction or its electrical circuit broken. Check the electrical circuit and connector contacts in the control unit. Check and, if necessary, replace the ignition transformer. The ionization electrode is faulty, its electrical circuit is broken, the gap between the ionization electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (3-3.5 mm). Replace the ionization electrode. Also, with error 01 (E2), the coolant overheating sensor may be triggered in heating mode. Find and eliminate the cause of overheating of the coolant. The coolant overheating sensor is faulty or its electrical circuit is broken. Perform an electrical circuit and contact test. Inspect the overheat sensor (should be closed at temperatures up to
95C). No flame due to gas valve failure. Perform a contact test at the valve connector and at the control box. If necessary, replace the valve.

Error 02 (E7)- Heat carrier overheating

Code 02 for models 7023, 7224, 8224. Code E7 for models 8023, 8029.

The fan is damaged (the motor winding burned out, the bearing is jammed, the impeller is jammed, the electric power circuit of the fan is broken). Check the integrity of the circuit and contacts in the connections. Ensure free rotation of the impeller. Replace fan if necessary. Also, with error 02 (E7), the coolant overheating sensor may be faulty or its electrical circuit may be broken. Check electrical circuit and contacts. Check the overheating sensor (should be closed at temperatures up to 95C). The coolant overheating sensor has tripped in heating mode. Find out and eliminate the cause of overheating of the coolant.

Error 03 (E6)- Malfunction in system of removal of products of combustion

Code 03 for models 7023, 7224, 8224. Code E6 for models 8023, 8029.

Clogged chimney or air intake duct. Clear pipes. The supply pipes or the housing of the air pressure switch are damaged. Repair damage or replace tubing. The electrical circuit of the air pressure switch is broken. Air pressure switch defective. Check the continuity of the circuit and contacts in the connections. Replace the sensor.

Error 04 (E1)- Lack of water pressure or lack of circulation in the heating circuit. The device does not start.

Code 04 for models 7023, 7224, 8224. Code E1 for models 8023, 8029.

Small amount of water in heating system. Top up the heating medium in the heating circuit to the required pressure. There is air in the heating system. Perform air removal from the heating system. Clogged dirt filter in the heating circuit. Carry out filter cleaning. Bypass valve defective or incorrectly installed. Check and, if necessary, replace the valve. Failure of the circulation pump. Replace the pump. Even with error 04 (E1), there is insufficient mobility or acidification of the flow sensor rod in the heating circuit, which transmits movement to the microswitch, a rupture of the flow sensor membrane. Remove the microswitch from the flow sensor housing. By turning the boiler on and off again (turning the pump on and off), release the fixed rod; if this does not help, check the integrity of the membranes on the flow sensor. The microswitch is defective, or the electrical circuit between the microswitch and the control unit is broken.
Check the electrical circuit and contacts in the control unit connector. Replace microswitch. Failure of the three-way valve drive servomotor. Replace servomotor. The gas supply is interrupted. Check the presence and pressure of gas at the inlet to the gas unit. Click on the Reset button. Not correct connection phases when connecting the unit to the mains. Make the correct connection of the phases.

Error 05 (E3)- Failure of the heating circuit temperature sensor. The appliance does not work either in heating mode or in DHW mode.

Code 05 for models 7023, 7224, 8224. Code E3 for models 8023, 8029.

Faulty heating circuit temperature sensor. Replace temperature sensor. Violation of the electrical circuit temperature sensor - control unit. Check electrical circuit and contacts.

Error 06 (E4)- Damaged DHW temperature sensor. The boiler will continue to operate in heating mode and hot water mode.

Code 06 for models 7023, 7224, 8224. Code E4 for models 8023, 8029.

Faulty DHW temperature sensor. Replace the DHW temperature sensor. Damage in the electrical circuit DHW temperature sensor - control unit. Perform an electrical circuit and contact test.

Error E8- Communication error

The loop connecting the controller board to the control board is damaged, or there is no contact in the loop connectors. Check the integrity of the loop and the presence of contact in the connectors. If necessary, replace the loop. Control board failure. Replace board. Controller board failure. Replace board.

Error E9- Supply voltage out of range

The boiler supply voltage is outside the range of 180 - 250 V. When the normal supply voltage is restored, the device will turn on automatically.

Troubleshooting

I have been using the Neva Lux gas boiler manufactured by Baltgaz for 2 years. Now in his work began to appear defects. If you use for a long time hot water, the pressure drops in the system and it stops with error 04. Although the pressure gauge shows the same pressure of 1.6 bar. account for
drink constantly. How can I fix this?

Your expansion tank may be under pressure. That's when error 04 is possible.

Six months ago, I installed a double-circuit boiler Neva Lux 8230. Recently I encountered such a problem. When hot water was needed, I opened the faucet as usual. It went warm at first, then cold again. Error 02 appeared on it at that moment. I tried to reset it with the "reset" key, but after that the heating turned on. After that, hot water was again required in the evening. Opened the faucet and everything worked fine. The device worked without problems for 4 days, but today the error appeared again. Studied more carefully. It happens like this. After the transition to DHW heating, a sound is heard inside, similar to the suction of air. At the same time, one can observe the instability of the pressure gauge readings (approximately 0.5 in each direction). And all this is accompanied by the same strong sound, not only from itself, but also from the membrane tank (additional, external 18l). After that, the pressure rises sharply already up to 5 bar. Switching off, the water temperature drops to 23C. And error 02 is displayed. The instructions say that I have air in the heating system, but I work with hot water. What is the connection? Maybe my three way valve is broken? Or is my filter clogged in the heating system itself?

Error 02 - the coolant is overheating. Perhaps the fan is broken or the sensor is damaged.

My Neva Lux 7023 boiler stops about 2 times a month with error 07. A reboot always solves this problem. And now a new error has appeared - E5. It works for a quarter of an hour and turns off. What happened to him?

Error E7 means that the coolant is too hot. Perhaps you have a heat exchanger with inside all in scale, and because of it, there is poor circulation in the system. Has it started making any unusual noises for you? But about E5, here you need to pay attention to the pressure switch or fan. You have to watch this and that. In a good way, this problem should be solved by a specialist. Also, just in case, check if your chimney is iced up.

The unit showed error 03. As I understand it, it means problems with the fan. When checking, I applied voltage to it - everything is normal. Also checked the pressure switch - also serviceable. Is it a relay on the board? I ran into something similar a couple of years ago. But then a friend helped me out, giving from his old unit. Tell me, is it possible to somehow work without this relay? I tried to manually spin the fan, it started working, but no gas came out. Is the relay responsible for this? But now the error was 01.

In order for the relay to work longer, you need to more carefully configure gas valve and heating power, and it is also desirable to install a room thermostat. All this not only increases the life of the device, but also saves gas. To solve error 01, you need to check the voltage on the gas valve, whether it opens normally and whether gas is flowing. It is better to call a specialist, since all these checks are associated with a risk to life. And the master has a differential. pressure gauge for assessing gas pressure. So, most likely you little house and you did not set up the system for the heated area. So a room thermostat is the best solution for you.

Help me please. In our new apartment, even before us, a wall-mounted double-circuit NevaLux 7218 was installed. During the day, it constantly stops by error 04. They began to feed it, then the temperature began to drop. And now water has also flowed from it (in the place where the heating pipe enters it). I had to turn it off. Does that mean they can't be used?

The pressure switch needs to be checked. The chimney could be clogged with a small air duct.

My wall-mounted boiler Neva Lux 7023 (Baltgaz) has a problem with hot water. With heating, everything is normal, and as soon as I start the analysis of water, an E2 error appears. The water does not heat up. If the water is closed, then it continues to heat the apartment quite normally. The water pressure is consistently good. I looked in the instructions, it says that E2 is an error of unsuccessful ignition or overheating of the coolant. During DHW operation, the burner starts and burns for 2 seconds. Then the thermometer shows a temperature of 95C, the device immediately turns off and an error occurs. The water is coming warm while the burner burns. What could be broken?

Try to check the DHW temperature sensor, this may be the case. Although, in theory, the E2 error symbolizes problems with ignition, but then there would be no heating.

My boiler manufactured by Baltgaz, installed on the wall, at first did not want to switch from the heating system mode to hot water supply. Although, sometimes, for reasons I do not understand, it still worked as it should. First of all, I checked that all contacts were in good condition, then I checked the electric motor three-way valve. If you clamp it with a screwdriver, then the valve is in good condition and works as it should. If you switch the mode (with the engine removed), then everything works. Stem movement is noticeable and consistent. Contacted the service center. The master who came to me suggested that the problem was in the duct sensor. He did not see the signal coming to him. Need a new one. But he did something to make the device work. He did not work for a day, and then I needed to turn it on. And it doesn't start. The indicator blinks, all possible characters are highlighted. Reboot didn't help. Disconnected the power - also did not help. What could be the problem?

Remove the connector on the board, and disconnect the wires one by one. First of all, those who are responsible for driving the three-way valve. Then reattach them. This should solve your issue.

I can’t fix the Baltgaz Neva boiler in any way. Error 03 constantly appears, the fan does not work during ignition. If you blow on the tube of the pressure switch, it starts to spin. The device does not want to turn itself off, you have to do it manually. How to be?

Find the hatch in the upper right corner. It needs to be opened and restarted.

Other malfunctions

No spark to ignite.

Faulty or poorly installed spark plug. Correctly install the candle (the gap between the end of the candle and the burner section is 4-5 mm) or replace it. Unreliable contact between the terminal and the ignition wire. Check the contact of the terminal with the ignition wire. Ignition electrode dirty. Wipe the electrode from dust and degrease.

The boiler does not turn on.

Lack of gas. Lack of water. Lack of electricity. Carry out appropriate checks (incoming gas, presence of water, connectors, fuses). Burner nozzles clogged. Clean nozzles.
Presence of air in the gas circuit. (May happen after prolonged inactivity). Switch on the unit several times until the error resolves itself. The fuse has blown. Replace the fuse on the controller board. Worked temperature sensor heating circuit. Check pump operation. If the pump is running, check the sensor. Defective gas valve. Repair or replace the valve. Deactivated boiler. Switch on the device again.

Pops in the burner.

Problems in the gas supply. Check the gas pressure in front of the unit. Dirty burner. Check and clean the burner. Insufficient air supply. Clean the burner. Poor flame adjustment. Check the gas flow and gas pressure before the burner.

The smell of gas.

Gas leak. Check the entire gas circuit for leaks using soapy water or a gas detector.

Small output of hot water or its absence.

Insufficient water pressure at the inlet. Increase the pressure by installing an additional inlet pump. Clogged water filter. Remove and clean the filter on the DHW line. Heat exchanger with partially or completely blocked tubes. Clean the heat exchanger tubes.

Cold radiators in winter.

Set too low temperature heating or the temperature sensor is defective. Install more high temperature heating or replace the temperature sensor. The pump is not working due to contamination. Remove the screw on the front of the pump and turn the spindle.

Hot radiators in summer

Winter heating mode. Set summer mode.

___________________________________________________________________________________________

___________________________________________________________________________________________

Borino, ZHMZ, Siberia, Alfa Kalor, Thermotechnician.
Adjustment gas automation Eurosit 630. Thermocouple replacement and pilot burner maintenance.

2017-05-17 Evgeny Fomenko

The device and principle of operation of the Neva Lux boilers

Neva Lux gas boilers are presented in two variations - wall-mounted and floor-standing, we will consider their device using some models as an example. Neva Lux 8618 is a single-circuit heating boiler, the installation method is wall-mounted, it has a low level of energy consumption, enough high efficiency 91%, power 18 kW. It can heat a room ranging from 30 to 180 square meters.

Works on both natural and liquefied gas. It has small dimensions, is equipped with a combustion chamber, which is cooled with water, it can also be connected to room thermostat which is convenient to use. Equipped with an overheating (boiling) protection device, a thermostat against overheating of the gas exhaust device. It can be connected to both a chimney and a turbo nozzle.

Neva Lux 8224 is a double-circuit gas boiler designed for heating a room up to 240 meters2, as well as for heating water for household needs, with a throughput of 14 liters per minute. Its power is 24 kW, it is equipped with a closed combustion chamber.

The installation method is wall-mounted, equipped with a built-in 6-liter expansion tank, which makes it possible to connect the boiler to a heating circuit of 70 liters. The design provides for two heat exchangers, copper for the heating circuit, and the second, made of stainless steel, for hot water supply.

Powered by natural or liquefied gas, for ease of use it has a display that reflects the current and set temperature in the coolant.

Neva Lux 7224 - installation method wall-mounted, double-circuit apparatus is designed to heat a room up to 240 m2, water throughput for domestic needs is 14 liters per minute. It can work on natural gas and liquefied gas, the efficiency is 92%.

Boiler Neva Lux 7224

Equipped with a bithermic heat exchanger, thanks to which it is possible to reduce the final cost of heat. It is equipped with an electronic self-diagnosis system, and a small display is installed on the body to indicate readings.

Neva Lux 7023 - wall-mounted, designed for space heating up to 250 meters2, as well as heating service water 13 liters per minute. It works not only on natural gas, but also on liquefied gas; for ease of use, you can connect a room controller.

The removal of smoke is forced, with the help of a built-in fan, the air for burning the fire is blown from the street. Equipped with a closed combustion chamber, has a coaxial heat exchanger, expansion tank volume of 6 liters.

Neva Lux 8023 - is a double-circuit wall-mounted boiler that has the ability to provide heat to a room whose area does not exceed 240 m2. The circulation of liquid in the system is forced, using a pump, equipped with a closed combustion chamber.

Smoke removal is due to exhaust fan. The power of the device is 23 kW, two heat exchangers are provided, the heating circuit is paramount, made of high-alloy stainless steel.

Basic error codes

Like any other device, it periodically fails, then we will consider in detail the error codes for the Neva Lux gas boiler.

Control Panel gas boiler Neva Lux

e1

Error e1. This malfunction indicates a low fluid pressure in the heating circuit.

The reasons may be as follows:


e2

Error e2. Failed ignition, check the following:


e6

Error e6. No traction. Check the possible causes of this malfunction:


e7

Error e7. Exceeding the permissible temperature in the coolant.

What are the possible reasons and what to do, we will consider in more detail:


01

Error 01. Malfunctions that occurred during unsuccessful ignition.

Possible reasons:


02

Error 02. Indicates that the boiler has overheated.

Possible reasons:


03

Error 03. In order to fix it, check:


04

Error 04. Low pressure in the heating circuit, you need to check:

  • Too much decreased pressure in the heating system, raise it to the recommended level.
  • Possibly in the system formed airlock , use the vent valve to remove it.
  • Broken pressure sensor in the heating circuit. Replace it.
  • The pump is broken, clean it and replace if necessary. Spend visual inspection all connections and connectors on the control board.

In the section on the question Boiler Neva Lux 8224. Constant error 03. Condensation accumulates in the pressure switch tubes. How to fix this problem. given by the author Vladimir the best answer is Need more detailed information about where it is located, external temperature, fuel (gas or diesel), winter or summer, etc. And condensate from what (water, gas)?
What can be done to prevent condensation from collecting in the Pitot tubes? The Neva Lux 8224 boiler turns off every year in January, showing error 03. Of course, I eliminate the condensate and start the boiler until the next accumulation of condensate, but this problem is pretty annoying. Help!

Answer from Yotas Shabanov[guru]
1. Check if the faucet is completely closed
make-up.
2. If the make-up valve is closed to the stop, then
it is possible that the feed valve is not tight.
Replace feed tap.
3. Check if the secondary heat exchanger is leaking.
4. Also check if the sensor is working
pressure and connectors of its contacts.
Another option: slightly opening the plug with right side
at the top, in order to enter the combustion chamber
hit warm air and not
condensation formed in the pressure switch tubes.