How to remove the air conditioner from the wall. How to dismantle a split system with your own hands: features and procedure for performing work Pump freon into the outdoor unit

For what reasons is the air conditioner removed and how to remove the air conditioner from the wall? There can be many reasons for dismantling the air conditioner. Such reasons include:

  • repairs that are planned on the premises;
  • changing the air conditioner to a newer model;
  • breakdown of the air conditioner and its replacement with a new device;
  • remove the device for the summer period.

Removal of oversized equipment

Removing the air conditioner from the wall with your own hands is not so difficult. Moreover, this will save money on the costs of service center specialists. To independently disassemble the design, you need to find out all the nuances of the operation and the sequence of actions. It is important to consider that each model of equipment has its own characteristics, so the sequence of actions may be slightly different.

No effort is required to turn off floor, flow or wall-mounted equipment. To turn off, it is necessary to close the supply of working fluid, turn on the air conditioner and drain the working fluid from the equipment, which can damage the furniture of the apartment. After all the liquid has been drained, you need to turn off the equipment from the mains and turn off the drain. Then you need to carefully, slowly, remove the device from the wall mount (this applies to ceiling and wall products that are hung on the wall and fixed with a special mount). Now we remove the tubes that supply liquid to the device, and finally remove and remove the air conditioner from the wall.

The most difficult removal actions split - systems

To remove the split system from the wall, you need to choose the right set of tools and keys of the right size. As a rule, some of the keys for installing and dismantling the air conditioner are included in the equipment package. The most important thing is to find a set of hex keys, without which it will be difficult to unscrew the protective screws, thanks to which the nozzles are in motionless movement. Branch pipes are necessary for supplying the working fluid of the equipment.

Then you need to unwind the pipes (the main thing to know is that in a system of this type it is impossible to pump the equipment in an idle way, so you should prepare a container in advance to drain the working fluid). First of all, you need to remove the thin pipe that lets the coolant through (it is called the refrigerant), then you need to turn on the device and wait a certain time until warm air comes out of the air conditioner. After that, unscrew the most thickened pipe and completely turn off the air conditioner.

The copper pipes of most models cannot be removed; to cut them off from the equipment, you can use metal cutters. The cut ends of the pipes must be compressed. Now there is very little left: completely turn off the electrical circuit of the device, remove the equipment from the attachment point, and then disconnect the outdoor unit of the air conditioner.

The monoblock system is removed in almost the same way. The only exception to dismantling is that there is a completely different electrical circuit here, and the nozzles containing the working fluid are very different.

If you are afraid to remove the device and turn off some equipment, you can use the user manual that came with the equipment or ask for help from people involved in dismantling the air conditioning system. In the instructions, you can find out in detail information on how to disconnect the drainage and other mechanisms of the product.

Before proceeding with dismantling, we recommend that you make sure that you have all the necessary tools.

Cassette devices

Cassette air conditioners are the most difficult, therefore, to remove the air conditioner from this type of wall, a separate approach is required. Consider dismantling the device in stages:

For the most detailed information on disabling the cassette unit, please refer to the user manual supplied with the air conditioning system.

To remove the bracket yourself, you need to read the literature on the repair, installation and dismantling of air conditioning equipment or consult with experienced people from the service center. If you are afraid to do the work of removing the air conditioner, in this case it is better to contact the employees at the service center and call the professionals in their field.

Channel view of air conditioners

There is another type of air conditioning equipment - channel devices, which are even more difficult to dismantle. The thing is that the design of this device is quite heavy and massive, since its system consists of numerous branched air ducts. These mechanisms are also subject to dismantling.

In equipment of this type, first of all, it is necessary to disassemble the air ducts, and only after that it will be possible to start removing the air conditioner. It is necessary to start removing the air duct from the grating of their exit into the space of the room, gradually moving from them to the connection connector.

After turning off all the pipes that serve for the inlet and outlet of air, you need to turn off the equipment itself. The most important thing when removing a duct device, like any other air conditioning equipment, is to turn off the pipes in time and drain the working fluid in a timely manner so that freon does not leak. After disconnecting the nozzles, the system should run in a little (just a few minutes is enough), and after that you should completely turn off the device and remove the electrical circuit.

The next step is to disconnect the shut-off valves from the air conditioner and remove these parts. Now you can start dismantling the external unit. To remove it, it is recommended to contact a specialist. The fact is that, firstly, you may not have the right tools available, and secondly, they have experience working at high altitudes and will easily cope with their task.

Being engaged in the removal of the device, one should not forget that during installation the equipment was well and quality fixed, adjusted and aimed at a long service life, therefore, during dismantling, it must be depressurized. During this procedure, it is necessary to ensure that freon does not get on human skin. The fact is that it can cause frostbite.

As follows from the article written above, the dismantling of air conditioning equipment is not such a difficult job, but still in some cases requires the intervention of professionals. All that can affect the complexity of the removable process is the model of the equipment and the method of its installation.

The article on how to remove the air conditioner from the wall is for people who like to do all the housework on their own. I hope that the information will be useful and will help you cope with this task without the need to contact specialists. Before proceeding with the dismantling process, it is important to carefully study all the information and consider each step step by step. This will avoid erroneous actions and possible injury. Of course, if you are sure that you can do the job and remove the device with your own hands, then we advise you to familiarize yourself with the security measures and proceed with the action.

Nevertheless, if you doubt the independent completion of the task, it is better to contact the professionals and pay for their services for the dismantling of the air conditioner. Moreover, you may not have the tools necessary for the job and you will have to spend time searching for or buying the missing keys.

Some people install air conditioners in their apartments in the summer to escape the hot weather. However, sometimes it is necessary to dismantle such a device. The reasons for dismantling can be different, but most often they are removed due to breakdowns. Before proceeding with the removal, you need to familiarize yourself with how to remove the air conditioner from the wall during the repair.

Before you start dismantling the device, you need to understand the features of its device. This will help to avoid unpleasant consequences during the work. The device consists of two main blocks - internal and external. They are combined with each other by lines that are needed to move the refrigerant.

Most often, it is in this part that there are problems that arise when a person tries to remove the device on his own:

  • improper shutdown of the main pipe, which leads to a partial loss of freon;
  • air entering the tubes, due to which the air conditioner may break;
  • the penetration of foreign objects into the main pipes, which leads to a deterioration in the circulation of freon.

Required Tool

There are several different tools that will be needed to complete the work.

pipe cutter

A pipe cutter is a tool used to cut pipes. It differs from a hacksaw in that it makes perfectly even cuts and does not create sawdust when working. During use, the pipe cutter is put on the pipe, after which it is carefully tightened and rotated around the axis. This is done until the pipe wall is completely cut.

Gauge manifold

This is a special device that is used to control the pressure inside refrigeration systems and air conditioners. Also, a manometric manifold is used to refuel and evacuate cooling systems. Collectors are connected to cylinders with refrigerants and refrigeration units, after which the system is filled with freon.

Keys

When dismantling air conditioners, three types of keys are used.

End hexagonal

Hex wrenches are considered a useful and indispensable tool that is used in the repair of various equipment. Hexagons are used while working with fasteners that have a hexagonal shape. For other fasteners, this tool will not work.

Horn

Open-end wrenches are considered the most common, and therefore they are in almost every home. This tool is used for screwing or unscrewing fixing nuts. During the use of such a key, the nut is clamped between two horns and begins to rotate. The advantages of open-end wrenches include versatility and ease of use.

Adjustable

Some people do not have an open-end wrench and therefore have to use adjustable models when removing the air conditioner. The disadvantages of such tools include the following:

  • the presence of a large head, because of which it is sometimes difficult to unscrew small nuts;
  • the impossibility of tight fixation of the nut;
  • gradual loss of performance.

Side cutters

This is the most popular cutting and biting tool that almost everyone has. These wire cutters are used to cut wires, wires or cables. Sometimes they are used to cut into pieces small metal sheets or plastic products.

Drill

The drill is considered an indispensable device that has many useful functions. Often it is used for drilling holes, grinding surfaces or driving screws. However, some types of products can be used to unscrew fasteners. It is this function that will be needed to dismantle the air conditioner.

Screwdriver Set

To quickly remove the cooling system from the wall, you will need a set of screwdrivers. When unscrewing the fixing screws, cross-shaped and straight screwdrivers are used. When doing this, it is better to use tools of different sizes, as the screws can be small or too large.

construction knife

A construction knife is considered a universal tool that is used not only by builders, but also by designers, needlewomen, and craftsmen who repair household appliances. Previously, such a knife was used only for cutting paper, but now they cut foam, leather, cardboard and even plastic.

How to release freon with your own hands

Before dismantling the air conditioner, it is necessary to drain the freon from the system. To do this, you must perform the following steps:

  • Close the valve located between the thin main tube and the device body.
  • Turn off the tap located on the thick pipe. This is done as the refrigerant moves into the condenser.

Dismantling sequence

outdoor unit

Dismantling begins with the disassembly of the outdoor unit. First, the thermal insulation of the structure is removed. Then the nuts responsible for attaching the air conditioner to the wall are carefully unscrewed. When the fasteners are unscrewed, the system is carefully removed. It is better to do this together so as not to damage anything.

indoor unit

To remove the indoor unit, follow the steps below:

  • remove the housing cover;
  • disconnect the cable that is responsible for the supply of electricity;
  • unscrew the pipe;
  • remove the heat insulator and disconnect the freon pipe;
  • unscrew the screws and remove the indoor unit with the mounting plastic.

Dismantling features

There are several features of dismantling, which must be familiarized with in advance.

Cassette devices

Some install cassette models of devices in the apartment. Their main feature is the presence of reinforced block protection. Before proceeding with the removal, it is necessary to get rid of it with the help of special electrical appliances. Then the device is disconnected from the network, after which the refrigerant is pumped out and the pipes are unscrewed.

ducted

Channel devices are more difficult to remove due to the fact that they are very large.

In what cases it is not necessary to dismantle

There are several cases when it is not necessary to completely dismantle the air conditioner:

  • Wallpaper re-gluing. Some remove structures when wallpapering, but this is not necessary. It is enough just to remove the case of the indoor unit.
  • Wall alignment. In this case, only the internal part of the system is also dismantled.

Common Mistakes

There are several common mistakes that are made when dismantling air conditioners:

  • improper disconnection of tubes;
  • improper refrigerant transfer;
  • use of inappropriate tools.

Conclusion

People who have air conditioning installed sometimes have to deal with removing it. Before that, you need to familiarize yourself with the basic recommendations for dismantling such systems.

The dismantling of this household system is carried out for subsequent repairs or when moving, many users solve the problem simply - they call the masters from the service center. A prudent owner who has the skills and desire can save money and do everything on his own, but we will tell you how to properly remove the air conditioner, while avoiding mistakes and negative nuances.

Any modern split system, which includes domestic air conditioning, consists of blocks for indoor and outdoor locations. They are connected by two lines through which the refrigerant moves. circulates through a tube of smaller diameter freon in liquid form from the indoor unit to the outdoor unit, it runs in the opposite direction along a thicker copper tube, but in a gaseous state.

This is where the problems lie that can spoil all your actions when trying to remove the air conditioner yourself.

  1. As a result of improper shutdown of main pipelines, partial or complete freon loss.
  2. Air containing moisture can get into the tubes and the heat exchanger, which is fraught with breakdown when the air conditioner is operating in a new place - incompressible moisture enters the compressor and disables it.
  3. Small particles entering the copper pipes when they are pulled through the wall or during improper transportation leads to a quick breakdown of the system.
  4. Particular attention should be paid to the threaded leads soldered to the tubes, if they are damaged, a very expensive repair will be required.
  5. Incorrect wire disconnection. If you do not put special marks on the terminals, it may lead to incorrect connection in a new place.
  6. Cutting too short drainage tube, which removes condensate outside the outdoor unit, you doom yourself to its premature complete replacement.
  7. During transportation of the product to a new place of service, there is a danger of losing small fasteners and parts if they are not securely fastened after disassembly.

All of the above cases lead to a very expensive repair of the entire system, so before you start dismantling the air conditioner with your own hands, read the instructions.

Training

Before dismantling the split system with your own hands, you need to prepare a tool, not a simple one from your home arsenal, but a purely professional one, as shown in the photo:

Many users do not take seriously the advice of professional craftsmen on how to properly dismantle any split system. As a result, the shutdown is carried out with numerous violations: they dismantle the product without pumping freon into the air conditioner, it leaks, which will not be as easy to make up as many people think.

A new filling of the entire system with refrigerant will result in serious financial costs:

  • first, the master will check the integrity of all pipelines - 600 rubles;
  • refueling an air conditioner with a power of up to 4.5 kW - up to 3 thousand rubles;
  • the same actions with equipment power up to 7 kW - up to 3.5 thousand rubles.

With the most minimal scenario for household air conditioners, this operation will cost you at least 4 thousand rubles, depending on the refrigerant used.

Freon descent

There are three ways to dismantle the air conditioner with your own hands:

  • disassembly with the release of freon;
  • save gas inside the air conditioner approximately or “by eye”;
  • completely save freon with the help of professional equipment, using a special technique.

The third option gives the best effect without any loss, but many users use all methods. Experts advise to completely store the refrigerant so that there are no problems when installing dismantled equipment in a new location.

To properly dismantle the air conditioner, you need to know the design of the split system, which consists of a closed circuit filled with freon. The main components are a compressor, an evaporator with a condenser and a system of copper pipes that connects the entire structure and ensures the supply and withdrawal of refrigerant.

This is how a schematic device of a modern air conditioner or any split system looks like:

To turn off the air conditioner yourself without losing freon, you need to pump it into the condenser, for this, when the equipment is operating in cooling mode, you should close the valve between the product and the thin-diameter tube. When all the refrigerant is pumped into the condenser for a minute - that is how long it will take for the gas to be completely pumped - it is necessary to shut off thick tube valve, turning off the freon supply, and "close" it in an impromptu trap.

Dismantling

Before dismantling the outdoor unit, you must disconnect copper tubes, but in practice they are not reused, because building them is strictly prohibited. It is necessary to cut them off at a distance of about 200 mm from the fitting and caulk the cuts for complete sealing.

Attention! When the product is disassembled for a long time, the tubes are filled with nitrogen, provide tightness to prevent oxidation of the inner surface.

outdoor unit

The instruction says: after working with copper tubes, you need to remove insulation, as a rule, all masters work together, one indoors, and the second outside. Thus, dismantling is faster: the partner turned off the power and now you can disconnect the wires at the place of their connection, previously by marking the terminals.

The tubes are straightened by hand so that they pass through the holes in the wall without interference, and the end of the cable is screwed to them to remove it inside the room.

After that, we unscrew the nuts that hold the outdoor unit on special brackets, together with an assistant carefully remove the unit and move it inside the apartment. Lastly, the brackets are removed from the wall of the building.

Important! The dismantled outdoor unit during transportation and during storage is located only vertically in order to exclude mechanical damage from shaking - it is inserted into a box with foam from the bottom.

Compressor

Sometimes only the outdoor unit is dismantled, for example, if only the compressor needs to be repaired, and the indoor unit of the air conditioner remains in place. During similar operations, the indoor unit of the split system is also not touched.

The main condition is to properly dismantle the compressor:

  • remove the cover from the outdoor unit;
  • then detach suction and discharge pipes;
  • all electrical wiring is turned off;
  • the fasteners of the condenser and fan are unscrewed;
  • remove the capacitor from the block housing;
  • access to the compressor is open - remove the fasteners and dismantle it.

With such actions, the risk of damaging the pipelines is eliminated and there is a real opportunity to repair other elements located in the outdoor unit case, if necessary.

indoor unit

Dismantling the indoor unit of the air conditioner has its own very specific nuances, without knowing which all your efforts will be useless, and in some cases, careless actions can lead to breakage of rather delicate fasteners, for example, evaporator latches or latches holding the unit on the rails.

To understand how to remove the air conditioner from the wall, you need to study the instruction manual, where there is a section that interests you. Many users will not be able to do this operation - they will have to turn to professionals.

Remove indoor unit the air conditioning system will turn out only after removing the front panel, then you still need to disconnect all the electrical wiring, the inlet and outlet pipes of freon. It is necessary to disassemble the plexus of wires carefully and without fuss. But this is not all the tests - manufacturers have reliably closed access to evaporator latches that dismantling is carried out only by specially trained people.

Access is closed by a cover, the latches of which are quite tightly pressed against the wall - you can get close to them using two screwdrivers with a very thin sting. Your partner must hold the entire block during this laborious process.

After removing the evaporator, you can unscrew mounting plate, which closes access to the electrical wires supplying the product and the freon pipes hidden in a special gutter inside the wall. The last to unscrew the decorative box, which runs along the outer wall to the very outdoor unit.

The disconnected wires are neatly twisted and folded into a separate box for transportation. To help home craftsmen, there is a video on how to dismantle the air conditioner on your own, without contacting specialists:

Dismantling in winter

Many users are interested in the question: how to remove a split system in winter, when due to low temperatures it is impossible to pump refrigerant into the condenser. The oil in the compressor will thicken, and all attempts to turn it on can end very badly.

If you have a special model equipped with a kit where there is a heater for the compressor crankcase and the entire drainage line, as well as a block that slows down the rotation of the fan, then your intentions will succeed. In its absence, you can use a special refrigerant recovery station, which is connected similarly to a manometric manifold.

A few more practical tips: you can start dismantling yourself only when you are completely confident in your own capabilities, and there is a qualified partner. Also, the presence of a special tool makes the job much easier.

It is as responsible to dismantle household climate equipment as it is to install it. Especially if its further use is planned, for example, when moving to another place of residence. Consider the basic rules of how to dismantle the air conditioner yourself without losing its effective performance.

Set of tools

Dismantling, as well as installation of the air conditioner, is strongly recommended to be trusted by professional installers. This largely guarantees a high-quality installation procedure, without the appearance of unpleasant consequences in both cases. But if there is no money for an expensive service, with certain skills, disassembly can be done independently.

The main point when dismantling a split system is careful, consistent observance of the basic rules that will preserve the functioning of the equipment. In many ways, special tools will be useful here that will help to disassemble with the least effort, with better quality. These include:

  • pipe cutter
  • side cutter
  • construction knife
  • Phillips screwdriver
  • integral screwdriver
  • hex socket wrenches
  • wrenches
  • adjustable wrenches
  • drill, screwdriver

A set of these tools is required because not many standard mounting tools will come in handy. Using the latter, it is likely to cause irreparable damage to the system, after which it will have to be changed.

How to properly dismantle the air conditioner? Safety regulations

There are certain rules, conditions that must be observed in order to protect health, equipment from breakdowns, malfunctions. Let's list them:

  • the cooling circuit must not be depressurized. It operates at a pressure of 15 A. With a sharp leak, there is a high probability of being hit by a very low temperature gas jet;
  • you can get frostbite from a jet of cold freon when it leaks;
  • it should be avoided when disassembling the ingress of dust, moisture into the circuit, which have a destructive effect on the system;
  • when transporting an outdoor unit containing freon, an explosion may occur;
  • during transportation, it is necessary to carefully handle the remaining pipe sections, as their damage will lead to the replacement of the entire unit;
  • it is forbidden to unscrew union nuts from fittings;
  • handle the latches of the indoor unit carefully so as not to break them.

Freon transportation

When dismantling the outdoor module, the primary task is to "pack" the freon. It is necessary to carry out this procedure with high quality, so as not to waste time and money on refueling the air conditioner. attention should be paid to the accuracy, accuracy of the transfer of refrigerant.

It is possible to reproduce with the help of a manometric manifold, or without it. This device will be able to show when a vacuum is reached in the cooling circuit. It is in this case that the second valve should be closed to “pack” the freon inside the condenser.

  • connect the gauge manifold to the nipple on the fitting instead of the branch pipe with the liquid of the cooling circuit (it is thinner compared to the second one, through which gas freon passes);
  • if the device is absent, it is necessary to start from the next point;
  • put the split system on cooling mode, determining the lowest temperature that the equipment is capable of according to its technical characteristics (you need to find out in the operating instructions). So the unit works for at least 10 minutes;
  • close the valve of the liquid pipe (thinner. It is closed with a hex key under the protective cap);
  • on the gauge manifold, watch the pointer until it reaches the vacuum level. If there is no pressure gauge, it is necessary to note 1 minute on the clock;
  • after the time has elapsed / the desired indicator is reached on the device, close the gas pipe valve with a hex wrench;
  • turn off the air conditioner;
  • put back the protective caps.

The difficult task of moving the refrigerant can become more difficult in the cold season, when the air conditioner cannot be turned on. The compressor oil thickens, its smooth operation is impossible. If the equipment is equipped with a "winter set" that allows the equipment to operate for cooling even at sub-zero temperatures, the problem is easily solved by starting the heating devices located in the compressor crankcase and drainage. After 10 minutes of warming up, you can start the climate system for cooling and pump freon, following the recommendations described above.

If there is no winter heating system, you can use a manometric station to collect the refrigerant. It is connected in the same way as the collector. Freon is distilled there for transportation.

Removing the outdoor unit. Is it possible to do it yourself?

After "packing" the coolant, you can proceed to remove the outdoor module from the mounts. How to dismantle the air conditioner with your own hands:

  1. disconnect the outdoor unit from the mains;
  2. if further use of the pipes is planned, they are unscrewed. Open fittings must be reliably protected from dust and moisture. In the case when reuse is not expected, copper pipes are cut off, leaving 15-20 cm of each branch from the fasteners. The ends are minted with a vice from moisture, debris;
  3. when it is known that the air conditioner will not be used for a long time, it is recommended to fill the remaining pipes with nitrogen, thereby displacing the air, and clog it. This will prevent the oxidative reaction of the metal with atmospheric oxygen;
  4. remove the thermal insulation from the freon circuit;
  5. disconnect the outdoor unit from the electrical cable by removing the pre-marked terminals;
  6. dismantle the nuts holding the module on the brackets, remove the module. It is recommended to do it together with an assistant, because the block is heavy, there is a high probability of dropping it;
  7. place in a special box with foam or other filler to avoid mechanical damage to the body, pipe bends;
  8. transport, store only in an upright position.

How to dismantle the indoor unit of a split system?

The indoor unit of the air conditioner is removed from the mounts only after dismantling the outdoor unit. Care must also be taken here, especially with the evaporator clamps of the equipment itself. If these elements are damaged, subsequently the newly installed unit will vibrate during operation, which will cause it to break.

How to dismantle the air conditioner yourself:

  1. remove the front panel so that you can get to the latches;
  2. disconnect the pipeline of the cooling circuit;
  3. turn off the power supply;
  4. remove the evaporator (carefully unfasten the latches closed by the lid)
  5. press the clamps of the indoor unit, remove it from the guides;
  6. dismantle the plate on which the indoor unit was attached;
  7. remove the cooling circuit pipeline from the wall gates;
  8. remove the drain pipe;
  9. dismantle the decorative box.

Consequences of incorrect dismantling

Here are some unpleasant consequences of inaccurate dismantling of the split system:

  • depressurization of the cooling circuit, as a result - freon leakage. When installing equipment again, you will have to pay for refueling the system with coolant;
  • mechanical damage to the case of the outdoor unit, outdoor module, any parts, freon pipes, especially if they lead to depressurization of the circuit;
  • clogging of the cooling circuit with dust, debris, moisture ingress. Dust will invariably affect the operation of the compressor, it will soon have to be replaced due to a malfunction. Moisture is dangerous because it will oxidize the inner surface of the copper freon path, the metal will begin to corrode, which will completely disable the system;
  • fall of the outdoor unit from a height. It doesn't matter how high it was fixed - a fall will result in its complete replacement anyway.

How to properly dismantle the split system will tell the video

When changing residence, they often carry an air conditioner with them, after all, the equipment is expensive. To do this without loss, it is strongly recommended to contact professional installers who will do everything correctly, efficiently. If the disassembly of the air conditioner is planned on its own, it is necessary to strictly follow the rules for dismantling, while doing everything as accurately, clearly, and smoothly as possible.

Friends! More interesting stuff:


Air conditioning

Do-it-yourself air conditioner dismantling is the operation on which you can save money. But is it really so? The fact is that most people do not know how to do it and, as a result, they get non-working climate control equipment. Air, getting into the split system, oxidizes copper pipes, as a result of which these devices are “killed”.

For the correct removal of climate control equipment, it is necessary to perform some preparatory work, namely, to prepare the necessary tools, shipping containers for the indoor and outdoor unit of the split system. Now it's time to prepare the conditioner itself.

Preparing climate equipment for shutdown and removal


The preparation is over, now it remains to dismantle the indoor and outdoor units of the air conditioner.

We remove the internal and external modules

It would seem that now, when all the freon is pumped into the condensation chamber, the main pipes are disconnected from the device, it is not difficult to remove it from the wall. But many people ask: "How to remove the air conditioner from the wall." There are few difficulties with the outdoor unit of a split system, and even then if it is installed on a balcony or within reach.

With the indoor unit of the climate device, everything is much more complicated. The whole catch is that it is almost impossible for an untrained person, especially one who does not have a specialized tool, to cope with the latches of fastening the block to the mounting plate.

Important!
When disconnecting and removing the indoor unit of the split system, a particular danger arises due to the possibility of deforming the evaporator pipes, which are located in close proximity to the air conditioner mount.

The dismantling process takes place in several stages

  1. Opening fasteners.
  2. Removal from the mount along the guides of the indoor unit.
  3. Remove the mount itself from the wall.
  4. Packing it for subsequent transportation.

Advice:
If you are unsure of your abilities or you do not have the necessary tools, then it is better to leave the job of dismantling the split system to professionals.

Removing the outdoor unit of the prepared split system can be done independently only if it is located on your balcony. In all other cases, you will need professional industrial climbers, because it is mounted on the wall of the house.

Removing the climate system is not particularly difficult, but before that, you should carefully consider whether the money saved is worth the lost time and health risks when dismantling it yourself?

Loading...
Top