Where to buy S2000 in Tyumen at the best price? Security and fire control panel S2000M Remote control s2000m instruction manual

    The following features have been added:
  • Added a new password attribute "duress code". When an object is controlled by a duress code, it is transferred to the "Coercion" alarm state. "Duress" is displayed as an alarm condition if the state alarm setting "PANIC" is set to "ALARM WITH AUDIO" or "ALARM WITH NO AUDIO", and is hidden if this setting is set to "NON ALARM". When a section is disarmed by a duress code, the event "DURLESS DISCONNECTED" is generated. The "Duress code presented" event is supported, which sets the alarm state "Duress" for the "reader" object (intended to generate an alarm when accessed by the duress code in the ACS). This alarm is cleared by the manual command "Reset alarms". The Duress state controls the outputs with programs 54 "Turn on when attacked" and 55 "Turn off when attacked" ("Attack" includes the states "Duress" and "Silent alarm").
  • Added the function of managing one presentation of the TM key / card to the reader. To do this, the access levels now have the "Management style" attribute, which takes two values: 1) "Display state, then manage"; 2) "Manage immediately." If the "Manage immediately" control style is set, then when a key with section control rights is brought to the reader, the section is controlled immediately. This management style is suitable for users with rights to manage a single partition.
  • Added alarm settings for events:
    • "Assault" (includes "Compulsion" and "Silent alarm");
    • "Entrance alarm".
  • Added relay control programs:
    • 54 "Turn on when attacked";
    • 55 "Turn off when attacked";
    • 56 "Lamp 2";
    • 57 "Siren 2".
    Programs "Lampa 2", "Siren 2" are intended for self-powered radio annunciators. A setting has been added that allows you to control relays with programs 1 - 8 with a delay in "Fire 2" (as in "S2000M" version 2.07).
    Changes to existing features:
  • For the convenience of using "S2000M", the user interface of the main mode of operation has been redesigned:
    • the number of necessary actions for viewing alarms, fires, starts, and malfunctions has been reduced. Changed the display of the number of sections with alarms, fires, launches, malfunctions;
    • the proposed control commands correspond better to the state of the partition and its type (for example, for a partition in alarm, a disarming command is suggested);
    • the events displayed on the screen in standby mode do not interfere with entering the password with the number buttons.
  • Added display of the number of sections containing executive devices that are blocked or in manual control mode (automatics disabled), added viewing of sections with automation states "Locked" and "Manual control" ("Automatics disabled"). Added a filter to the event log by the "Blocking" event type;
  • Event broadcasting setting for the S2000 Console object in the PProg program now only affects the prompt display of ongoing events on the screen, and all events are available in the log. This makes it possible to disable the online display of events. When the event display is disabled, the indication of the object state - the presence of alarms, fires, starts, stops, malfunctions and shutdowns - is preserved.
  • The user number is added to the "Partition Armed" and "Partition Disarmed" events if a partition (a group of partitions) is armed or disarmed not entirely by the partition control command, but in parts. Examples:
    • the section (group) was armed (disarmed) as a result of local control of the loops of this section (arming or disarming with keys recorded in the "S2000-4", "Signal-10" receiving and control unit);
    • a group of partitions has been armed (disarmed) as a result of arming (disarming) of the partitions of the group. Also, the "Partition removed" event is generated when it is disabled. These changes are useful when using notifications in the Ademco Contact ID or LARS protocols.
  • Two parameters have been added to the LARS protocol settings: which user number to transmit in the "partition taken" and "partition removed" events if the user number is not known, and which user number to transmit if the user number in the event exceeds the maximum possible value. The default settings of these parameters correspond to the operation tactics of "S2000M" version 2.06: "partition taken" and "partition removed" events are not transmitted if the user is unknown, and events with a too large user number are transmitted with the maximum allowable user number. The tactics of "S2000M" version 2.07 can be obtained by setting "1" as the number for an unknown user.
  • Changed event names: "WATER LEAK" to "FLOODING", "NO WATER LEAK" to "RESTORED DZ", "REMOV OVERLOAD RIP" to "CURRENT OK".
    Bugs fixed:
  • It was possible to turn on the relay once, after configuring it with the PProg program, if the relay control programs were changed.
  • Fixed a bug in the "input loops" function. The conflict of "input loops" configured simultaneously in the "S2000M" and the receiving and control unit has been eliminated (if configured simultaneously, the "input loops" will work according to the settings of the receiving and controlling unit).
  • An event with the result of the operation was not displayed when the control panel's AL was directly controlled (password with access level 253 - 255).
  • The "Partition taken" event was not generated if the section was armed with a key with control rights for an alarm loop (a key recorded in the "S2000-4" or "Signal-10" receiving and control unit), and there was an alarm loop with arming delay in the section for protection. The messages "Section taken" / "Section removed" could not be generated if some of the section inputs were set / removed by AL control scripts.
  • If the user first selected an action with the "RESET", "START", "STOP" key or pressed the context menu key, then he was identified (entered the password) and then exited the partition view with the " ×", the message "Invalid Partition" might be displayed.
  • There could be no initial indication of the state of actuators (outputs of the "process equipment" type) on the "S2000-BI / BKI" after the "S2000M" was taken out of the programming mode until the state of the actuators changed.
  • Transmission of control requests from "S2000-K" and "S2000-KS" to the "Orion Pro" workstation did not work when the "CENTRAL MANAGEMENT" parameter was enabled.
    Compatibility Information:
  • Configuration by "Pprog.exe" version 3.03 build 1 or higher.

Price: 6,665.00 rub.

Description

Control panel with two-line LCD indicator, number of controlled sections - 511, number of controlled groups of sections 128, number of controlled zones 2048, supply voltage 10.2...28.4 V, current consumption 60 mA, real time clock battery CR2032, degree IP30 shell protection, operating temperature range -10...+55°C, overall dimensions 140x114x25 mm

Purpose

The fire and security monitoring and control panel "S2000M" is designed to work as part of an addressable fire and security alarm system and control fire fighting equipment. Together with the Orion ISO devices, it can perform the functions of a block-modular security and fire alarm control device, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, building engineering systems. The information interaction of the blocks is carried out via a wired communication line RS-485. The functions of the device can be expanded by connecting additional blocks.

Specifications

  • Number of connected devices 127
  • Number of partitions supported 511
  • Number of partition groups supported 128
  • The maximum number of input circuits of devices controlled by the console 2048
  • Number of user passwords 2047
  • Maximum number of instrument outputs controlled by the remote control 256
  • Event Buffer Capacity 8000
  • Supply voltage, V:
  • - from an external power source 10.2…28.4
  • Current consumption in standby mode, mA, not more than:
  • - at a supply voltage of 12 V 60
  • - at a supply voltage of 24 V 35
  • Communication line length via RS-485, m, no more 3000
  • Degree of protection IP30
  • Operating temperature range, °C-10…+55
  • Overall dimensions of the console, mm 140x114x25
  • Weight, no more than, kg 0.3

Peculiarities

Indication of the modes "Alarm", "Fire", "Start", "Stop", "Fault", "Disabled". The ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound signaling of alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire fighting equipment and other actuators on the S2000-BI, S2000-BKI, S2000-PT, Potok-BKI units
Automatic control of means of light and sound notification, smoke protection, engineering equipment, signal transmission outputs "Alarm", "Fire", "Start" and "Fault" using control-start and signal-start blocks, receiving-control blocks. Automatic start and stop of devices of the voice notification of the Rupor series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
Manual control from the keyboard of the remote control and display units:
management of security and fire alarm modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
manual start and stop of light, sound and voice warning, smoke protection, engineering equipment;
control of "S2000-ASPT" devices using "S2000-PT" blocks: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode of the fire extinguishing installation, alarm reset;
control of Potok-3N devices using Potok-BKI blocks: manual start and stop of the fire extinguishing installation, selection of automatic or manual control mode of the installation
Possibility of connection to AWP "Orion Pro" to expand the possibilities of monitoring the state of the protected object and control
Possibility of transmitting notifications to the security console using communication blocks "S2000-IT", "UO-4S", "S2000-PGE" and "S2000-PP". Possibility to connect the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") or TRX-150 radio security system for transmitting notifications via radio channel
Event log with the ability to view it on the remote control screen and print on a printer with a serial RS-232 interface
Configuring the remote control in the program "Pprog.exe"

Where to buy S2000 in Tyumen at the best price?

The control panel is used as one of the elements that make up the fire and security alarm system. The device is designed to monitor the situation at the facilities, as well as collect data, indicate an alarm. Thanks to the remote control, all devices are combined into a single system and interact smoothly with each other. All changes that occur, for example, arming or disarming the object, a message about fires or malfunctions, are reflected on the display.

Buy S2000 in Tyumen offers the company "MAYAK - Security Systems". The purpose of the work of the company's specialists is to promptly provide customers with the necessary equipment. To do this, employees of "MAYAK - Security Systems" keep track of new products, study the security equipment market, and also optimize work in order to organize the supply of products as soon as possible and without delay.

You can check the prices of the devices with the employees of the company. Having bought S2000 KDL from the MAYAK - Security Systems company, you can be sure that the cost of the product and its quality will be in the optimal ratio.

The company's specialists will be happy to answer your questions and help you calculate the cost of your purchase. In order to get professional advice and order the necessary devices, please call the numbers listed on the site.

We are sure that now you have no doubts where to buy S2000 in Tyumen at an attractive price!

The fire and security monitoring and control panel "S2000M" is designed to work as part of an addressable fire and security alarm system and control fire fighting equipment. Together with the Orion ISO devices, it can perform the functions of a block-modular security and fire alarm control device, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, building engineering systems. The information interaction of the blocks is carried out via a wired communication line RS-485. The functions of the device can be expanded by connecting additional blocks.

Peculiarities

Indication of the modes "Alarm", "Fire", "Start", "Stop", "Fault", "Disabled". The ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound signaling of alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire fighting equipment and other actuators on the blocks "S2000-BI", "S2000-BKI", "S2000-PT", "Potok-BKI"
Automatic control of means of light and sound notification, smoke protection, engineering equipment, signal transmission outputs "Alarm", "Fire", "Start" and "Fault" using control-start and signal-start blocks, receiving-control blocks. Automatic start and stop of devices of the voice notification of the Rupor series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
Manual control from the keyboard of the remote control and display units:
management of security and fire alarm modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
manual start and stop of light, sound and voice warning, smoke protection, engineering equipment;
control of "S2000-ASPT" devices using "S2000-PT" blocks: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode of the fire extinguishing installation, alarm reset;
control of Potok-3N devices using Potok-BKI blocks: manual start and stop of the fire extinguishing installation, selection of automatic or manual control mode of the installation
Possibility of connection to AWP "Orion Pro" to expand the possibilities of monitoring the state of the protected object and control
Possibility of transmitting notifications to the security console using communication blocks "S2000-IT", "UO-4S", "S2000-PGE" and "S2000-PP". Possibility to connect the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") or TRX-150 radio security system for transmitting notifications via radio channel
Event log with the ability to view it on the remote control screen and print on a printer with a serial RS-232 interface
Configuring the remote control in the program "Pprog.exe"

S2000-ASPT fire extinguishing control device, Potok-3N water fire extinguishing station control device, S2000-KPB and S2000-SP1 relay modules, Rupor voice alarm device, system status indication units: S2000-BKI, S2000-BI, S2000-PT and S2000-BI version 01, devices for transmitting notifications via the S2000-IT telephone line and the UO Orion GSM channel, the S2000-2 access controller, additional remote keyboards S2000K and S2000-KS, as well as in the ISO AWP system "ORION" and "Orion Pro".

Addressable receiving and control panels of the S2000 series (analogue and addressable alarm loops) have stable characteristics, and belong to the "Universal alarm systems" category.

Control of up to 127 devices (Bolid address system) connected to the console via the RS-485 interface;

Display on the LCD (liquid crystal) indicator of events occurring in the system;

Storage in a non-volatile buffer of events with the ability to view on the display and print them on a printer with a serial interface RS-232;

Signaling alarms and events with a built-in sound signaling device;

Management of taking / removing and monitoring the status of alarm loops from the remote control;

Programming the configuration parameters of devices, printing the configuration on a printer, setting the addresses of devices and addressable devices;

Restricting access to control and programming functions using passwords.


Specifications S2000M (Bolid)

PARAMETER NAME PARAMETER VALUE
Number of devices and devices ISO "Orion" connected to the RS-485 line, not more than
RS-485 interface 1
Communication line length RS-485, no more 3000 m
RS-232 interface 1
Number of devices connected to the RS-232 output

1
(computer with workstation, printer, ATS100 or TRX-150 radio transmitter (via converter) or RS-202TD radio transmitter)

Communication line length RS-232, no more 20 m
Number of alarm loops and addressable detectors grouped into sections, no more than 2048
Number of relay outputs controlled in automatic mode, no more 256
Number of sections, no more 511
Number of partition groups, no more 128
Number of user passwords, no more 2047
Overvoltage protection 2 steps
Event log size 8000
Liquid crystal display 2 lines x 16 characters, backlit
Food from a redundant DC source
Supply voltage 10.2 to 28.4 V
Average current consumption in standby mode at a supply voltage of 12 V / 24 V 60 mA / 35 mA
Maximum current consumption in alarm mode at a supply voltage of 12 V / 24 V 120 mA / 65 mA
Working temperature range from minus 10 to +55 °C
Degree of protection of the shell IP30 (when wall mounted)
Weight, no more 0.3 kg
dimensions 140x114x25 mm
Type of connection to the device screw terminal block, wire from 0.2 to 1.5 sq. mm
Mounting method wall mounted

The full list of functions of the fire and security fire control panel Bolid S2000M:

Possibility to combine individual OPS loops into sections, while supporting a larger number of loops than the previous S2000 analogue, which allows it to be used on especially large objects;

Displaying text titles on a large LCD, sections and user names in the event log. The length of the display line is 32 characters. Now it is possible to set a textual description of users, partition groups, partitions and alarm loops;

Increased maximum number of system users (PIN and TouchMemory);

Sections can be combined into section groups. This allows group control of arming and disarming. Any group can include any section of the system;

Controlling the arming, dismounting and monitoring of the status of system sections, both from the console and from the S2000-K keyboard, the S2000-KS console and the S2000-4 device. At the same time, the control powers are delimited by passwords (the control rights for arming/removing partitions are set for users and separately for each connected device).

Possibility of software automatic control of relay outputs of relay blocks S2000-SP1, S2000-SP2 and S2000-KPB linked to the state of partitions. Possibility to control the outputs of devices S2000-4, Signal-20P and Signal-20 series 02. and other ISO Orion devices. Possibility to control relay outputs with preset delay time;

Control of the display of partition states on the S2000-BI and S2000-BKI display units (and other display units);

The S2000M console transmits (duplicates) the events occurring in the system to the S2000-K keyboards for their display on the indicator and the S2000-IT information transmission device (informer);

For convenient logging of events and displaying the status of sections and loops of the security and fire alarm, the control and management panel can be connected to a personal computer with the software AWP "Orion Pro";

Also, in the "programming" mode, the remote control can perform the function of an interface converter RS ​​232 - RS 485. This function allows you to configure the remote control and devices connected to it of the Bolid address system;

The console has the ability to connect several subsystems of the fire and security alarm system based on the S2000M console to a personal computer with the Orion workstation;

S2000M, when disconnected from the PC, switches to offline mode and continues to work with the specified configurations;

Programming and configuration of the S2000M control and management console is carried out using the program (utility) "pprog.exe" or the "Database Administrator" program from the "Orion Pro" workstation, which can be downloaded on the official website of the Bolid company, or on the website of the company "ABars" in the "Documentation" section (there you will also find the connection diagram and the passport of this network controller).

A wide range of devices for fire alarms of the BOLID brand allows you to choose a model for any request and functionality. A large selection will delight companies involved in the installation of fire and security alarm systems and their customers.

Although the S2000M belongs to the category " inexpensive remote controls", it is reliable, like all other elements of the Bolid trademark.

Office alarm;
Security and fire alarms for cafes and clubs;
Alarm to the store;
Security systems for warehouse and service premises;
Autonomous alarm system for an apartment, house or cottage;
Fire alarms for covered parking lots, garages and parking lots;
Comprehensive protection for state institutions (kindergartens, schools, other educational institutions)

When choosing, pay special attention to a careful study of the technical characteristics, the choice of suitable security detectors, fire detectors, special cable products. Devices of the S2000 line are among the best in terms of price-quality ratio and are recommended for use in a wide range of fire and security alarm systems. All control panels (PKP) of this brand have the ability to operate with most of the backup power sources presented on this site.

S2000M analogues and other devices similar in characteristics: S2000

Buy and order delivery of fire alarm systems in Moscow:

You can order and buy the S2000M remote control, as well as other Bolid products (their analogues, detectors, relays) through the fire alarm online store of our website or order delivery and professional installation services at your premises in Moscow from the ABars company. (Attention, delivery is free of charge for orders over 60 thousand rubles).

Loading...
Top