Foam generator stationary gpss. Foam generators of medium and high expansion Dimensions of the cabinet for the foam generator gpss 600

OKPD2 28.99.39.190

OKP 36 89

The foam generator is a component of vertical cylindrical storage tanks for oil and oil products and is designed for stationary fire extinguishing systems with air-mechanical foam using the overlayer method.
The foam generator is produced in climatic version T, U and UHL, placement category 1 in accordance with GOST 15150-69.


TU-3689-043-00217633-2001

1. GPSS - medium expansion foam generator;

2. Productivity, l/h:
600; 2000;

3. Modification of the medium expansion foam generator:

WITHOUT MARKING - corresponds to the foam generator with a vertical arrangement of the GPSS-2000 type;
A - a foam generator with a rectangular body and a lever system for automatic shutter operation.
M - foam generator with a round body and an eccentric mechanism for automatic shutter release. Additional index in the designation of the modification of foam generators of type A and M (1 - version with a square flange; without designation - version with a rectangular flange)

4. Material design code:

D - steel 20;
D1 - steel 09G2S;

U1 - moderate;
UHL1 - moderate and cold;
HL1 cold;

6.Package code for the foam generator (a combination of numbers is possible):

NO VALUE - without a complete set;
1 - flange according to GOST 33259-2015;
2 - gaskets for mating flanges
(G - thermally expanded graphite;
P - paronite PMB; P1 - paronite PON;
P2 - gasket for connection with the tank paronite PMB)
3 - fasteners;
4 - inclined section of the mortar pipeline; 5 - adapter flange for low-expansion foam chamber;
6 - mounting flange of the foam generator;
7 - adapter flange from the rectangular pipe of the tank to the square flange of the foam generator type GPSS-2000A1, GPSS-2000M1.

SPECIFICATIONS

Name
parameters
600A 2000 2000A 2000A1 2000M 2000M1 600M1
Pressure
before sprayer, MPa
0,6-0,8






Foam solution consumption, l/s 5-6






Foam ratio, not less 70
70
70
70
70
70
70
Actuation force of the manual drive, N 80-90

80-90
80-90
60-150
60-150
60-150
Dimensions,
mm, no more than:

Length
Width
Height
Diameter

620
570
570

1220


710

925
1110
610

925
610
610

890
1110
610

890
610
610

620
570
570

Weight, kg, no more 60
54
100
90
70
60
50
Productivity, l/s, not less 600
2000
2000
2000
2000
2000
600
Service life, years, not less 10
10
10
10
10
10
10

Overall and installation dimensions

GPSS-2000A GPSS-2000A1

GPSS-2000M1 GPSS-2000M

GPSS-2000

GPSS-600M1GPSS-600

*Foam-draining chamber is supplied at the request of the customer.

Foam mixer PS-2 80 mm is designed to produce an aqueous solution of a foam concentrate used to form foam in medium expansion foam generators in accordance with GOST 12962-80 and air-foam shafts in accordance with GOST 1101-93. Foam mixers are produced with connecting heads according to TUU 29.2-30711025- 12-2001, suction hoses according to GOST 5398-76. The principle of operation of PS-2 The principle of operation of the foam mixer is as follows: water under working pressure enters the nozzle, and from it into the neck of the housing diffuser. In the housing cavity adjacent to the nozzle, a vacuum is created, due to which the foaming agent is sucked along the hose into the housing diffuser, where it mixes with water. The resulting foaming agent solution is then fed through pressure hoses or pipelines to the medium expansion foam generator GPS-600. To prevent water from entering the container with the foam concentrate in the event of a sudden increase in pressure, a non-return valve is provided at the outlet of the foam mixer (for example, when pressure hoses are kinked). Maintenance of the foam mixer PS-2 lines, as well as when designing pipelines, one should be guided by the water flow indicated in the table and the maximum allowable backwater. It must also be taken into account that the total flow of water from the foam concentrate passes through the hoses behind the foam mixer. The resistance of the pipelines connecting the foam mixer to the GPS-600 generators must be such that: -0.6 MPa in front of all GPS-600. Limit value of the foam mixer level in the tank: - 0.3 m below the foam mixer axis - lower level; -2 m above the foam mixer axis - upper level. Preparing the foam mixer for operation consists in laying hose lines and connecting them to the foam mixer and GPS-600 generators. In this case, it is necessary to ensure the direction of water movement, indicated by an arrow on the foam mixer body. A periodic check of the serviceability of the foam mixer is carried out when it works on water instead of a foam concentrate. Water suction should be in the range of 0.30-0.36 l / s. without packaging in a container, provided that it is protected from damage. Foam generators, foam concentrates, foam mixers

The inlet of the GPSS foam generator is located on the flange 3. The solution pipeline of the stationary fire extinguishing system 6 is connected to it.

The equipment is fastened to the tank with oil products using a mounting flange 2. The flange has an outlet closed by a cover 9, which is mounted on a hinge 10.

In front of the sprayer 8 there is a damper 11, which is one of the arms of a two-arm lever installed in the body of the foam generator 1 on a hinge 12. The other end of this lever is connected by a hinge 13 to the fork 14.

In addition, the two-arm lever of the foam generator is connected by a rope 15 to the handle 16 of the manual drive. With its free end, the fork 14 is installed on the stop 17, fixed in the foam generator housing 1 with a bolt 18.

The rod 19 is connected with its ends to the cover of the foam generator 9 and 20.

The cover 9 is drawn to the edge of the outlet of the foam generator by the rod 19 due to the force created by the rotation of the nut 21 along the thread of the stud 20. In this case, the nut 21 rests against the fork 14 with its end surface.

The position of the nut 21, corresponding to the required sealing force of the junction of the cover 9 and the edge of the outlet of the foam generator, is fixed on the stud 20 with a lock nut 22. The limiter 23 of the opening angle of the cover 9 is attached to the stud 20 and the rod 19. The second end of the limiter 23 is bolted to the upper part of the body.

To protect the lever system GPSS foam generator during transportation, the plug 14 is fixed with wire 24.

Fire-technical products Stationary foam generator GPSS is used in stationary fire extinguishing installations for vertical tanks with oil (petroleum products).

Designed as equipment for tank farms, GPSS-600 and GPSS-2000 foam generators can be used in other industries within the limits of technical specifications. The inlet of the generator is located on the flange, to which the mortar pipeline of the stationary fire extinguishing system is connected. Installation and fastening of the generator on the tank is carried out using a mounting flange, on which there is an outlet closed by a lid, which is mounted on a hinge. Available with counter flanges.

Climatic modification - U.

The service life of the GPSS foam generator is 10 years.

» TU 112-025-85

» Certificate of conformity С-RU.ПБ01.В.02124 from 03.08.2012 to 03.08.2017

Specifications of the foam generator
Parameters / Name GPSS-600 GPSS-2000
Foam ratio At least 70
Nominal pressure, MPa 0.4-0.6
Foam capacity, l/s 600 2000
Solution consumption, l/s 5-6 17-20
Length, mm 675 980
Width, mm 570 620
Height, mm
Weight, kg 33 53

The device, the principle of operation of the foam generator

The atomizer forms a jet of the foaming agent solution in the form of a torch falling on the surface of the cassette. The meshed surface of the cassette promotes the formation of multiple foam bubbles by injecting air through an intake in the bottom of the foam generator housing. The foam created in this way is directed to the gas-air space of the tank to extinguish the fire.

The inlet of the GPSS foam generator is located on the flange 3, to which the solution pipeline of the stationary fire extinguishing system 6 is connected. The foam generator is installed and fixed on the tank using the mounting flange 2, on which there is an outlet closed by a cover 9 mounted on a hinge 10.

In front of the sprayer 8 there is a damper 11, which is one of the arms of the two-arm lever installed in the foam generator 1 housing on the hinge 12. The other end of this lever is connected by a hinge 13 to the fork 14. The two-arm lever is connected to the handle 16 of the manual drive with a rope 15. The free end of the fork 14 is installed on stop 17, fixed in the foam generator body with one bolt 18. Rod 19 is connected with its ends to covers 9 and 20. Cover 9 is attracted to the edge of the outlet of the foam generator by rod 19 due to the force generated by the rotation of the nut 21 along the thread of the stud 20. At the same time the nut 21 rests against the fork 14 with its end surface. The position of the nut 21, corresponding to the required sealing force of the junction of the cover 9 and the edge of the outlet of the foam generator, is fixed on the stud 20 by the lock nut 22. The limiter 23 of the opening angle of the lid 9 is connected to the stud 20 and the rod 19. The second end limiter 23 is bolted to the upper part of the housing.

To protect the lever system of the foam generator from breakage, the fork 14 is fixed during transportation with wire 24.

Stationary foam generator GPSS-600, GPSS-2000, GPSS-2000 A

  • GPSS foam generators are designed to supply foam when extinguishing a fire in a tank.
  • Foam is introduced into the tank through foam chambers mounted in the upper belt of the tank.
  • The foam breaks the membrane (a fragile vessel) made of oiled cardboard or sheet lead, enters the surface of the oil product and stops burning.
  • Usually 3-5 foam generators are installed.
  • GPSS 2000A- modification with a guide casing that prevents the weakening of the pressure of the foam concentrate.
  • The GPSS foam generator is installed on steel vertical tanks with a volume of 5000 m3 and more.
  • Foam is supplied to tanks with a fixed roof based on foam covering the entire area of ​​the product surface, and to tanks with a floating roof - based on the annular space between the tank wall and the metal diaphragm of the floating roof.
  • Stationary medium expansion foam generator GPSS is designed for use in stationary foam fire extinguishing installations for tanks with oil and oil products.
  • The generator can be used for this purpose in other industries within its technical capabilities.
  • The generator complies with the climatic version U, placement category 1, operating conditions in an atmosphere of type II GOST 15150-69.
  • GPSS is part of an automatic stationary fire extinguishing system in tanks for storing oil and oil products, the use of which is mandatory in accordance with PB03-605-03p.8.4.
  • In the event of a fire, the tank may deform due to an increase in internal pressure. This leads to the destruction of the pipes supplying the water solution to the GPSS.

Device and principle of operation: (see picture below)
The inlet of the foam generator is located on the flange 3, to which the mortar pipeline of the stationary fire extinguishing system 6 is connected.
Installation and fastening of the foam generator on the tank is carried out using a mounting flange 2, which has an outlet closed by a cover 9, which is mounted on a hinge 10.
In front of the atomizer 8 there is a damper 11, which is one of the arms of a two-arm lever installed in the body of the foam generator 1 on a hinge 12.
The other end of this lever is connected by a hinge 13 to the fork 14. In addition, the two-arm lever is connected by a rope 15 to the handle 16 of the manual drive.
With its free end, the fork 14 is installed on the stop 17, fixed in the foam generator housing 1 with a bolt 18.
The rod 19 is connected with its ends to the cover 9 and 20.
The cover 9 is drawn to the edge of the outlet of the foam generator by the rod 19 due to the force generated by the rotation of the nut 21 along the thread of the stud 20. In this case, the nut 21 rests against the fork 14 with its end surface. foam generator, is fixed on the stud 20 with a lock nut 22.
The limiter 23 of the opening angle of the cover 9 is attached to the pin 20 and the rod 19.
The second end of the limiter 23 is bolted to the upper part of the body.
To protect the lever system of the foam generator from breakage, the plug 14 is fixed (only for the period of transportation) with wire 24.
The description of the initial position of the lever system and cover 9 corresponds to the standby mode of operation of the foam generator installed on the tank.
To use a stationary medium expansion foam generator in operating mode (during fire fighting), a foam concentrate solution under pressure is supplied to the generator.
By the pressure of the jet from the sprayer 2, the damper 11 rotates around the hinge axis 12 and removes the fork 14 from the stop 17.
Under the action of the initial tension of the rod 19 and the rotation of the damper 11, the fork 14 rotates around the axis of the hinge 13 and disengages from the nut 21. In this case, the tension of the rod 19 disappears and under the pressure of the jet of the foam solution, the cover 9 rotates around the axis of the hinge 10 at an angle of about 90 ° and opens the outlet of the foam generator.
The atomizer 2 forms a jet of the foaming agent solution in the form of a torch falling on the surface of the cassette 3.
The mesh surface of the cassette 3 contributes to the formation of many foam bubbles due to the injection of air through the intake hole in the lower part of the GPSS-600 foam generator housing.
The foam created in this way is directed to the gas-air space of the tank to extinguish the fire.

Technical characteristics of GPSS stationary foam generator:
Name of parameters GPSS-600 GPSS-2000 GPSS-2000A
Pressure in front of the sprayer, MPa 0,6 - 0,8
Foam solution consumption, l/s 5-8 17-21
Foam ratio, not less 70
Pressure in front of the atomizer with automatic shutter actuation, MPa, no more 0,32
Actuation force of the manual drive, H at least 80
no more 90
Overall dimensions, mm, no more length 600 900 920
width 570 620 1100
height 570 620 610
Weight, kg. 34 52 100
Stationary foam generator GPSS600, GPSS2000, GPSS2000A price:
Name Meas. Price,
rub. VAT included
transport kit,
Price, rub. VAT included
Stationary foam generator GPSS-600 PCS 6 900 7 000
Stationary foam generator GPSS-2000 PCS 9 100 9 200
Stationary foam generator GPSS-2000 A1 (reduced flange) PCS. on request on request
Stationary foam generator GPSS-2000 A PCS 10 100 10 200